esp-idf/examples/protocols/modbus/serial
Alex Lisitsyn 16e6e63694 driver: fix driver set rx timeout feature of uart
tout_thr - move calculation and masking into hal layer update driver and uart_ll (add uart_ll_set_rx_tout)
move tout calculation into uart_ll
move calculation of time out in bit time for esp32s2 into low level uart_ll.h file
move uart_hal_get_symb_len() into hal
update set_rx_timeout() to warn user about incorrect value
update HAL, LL 1
fix uart_xx_set_rx_tout() to convert symbol time into bit time
update param description
update tout calculation in LL
update uart_hal_get_max_rx_timeout_thrd() and uart_ll_get_max_rx_timeout_thrd()
2020-03-27 16:20:21 +08:00
..
mb_example_common freemodbus: fix merge issues 2019-12-10 14:30:25 +08:00
mb_master driver: fix driver set rx timeout feature of uart 2020-03-27 16:20:21 +08:00
mb_slave driver: fix driver set rx timeout feature of uart 2020-03-27 16:20:21 +08:00
README.md freemodbus: fix merge issues 2019-12-10 14:30:25 +08:00
example_test.py freemodbus: update poll event processing 2019-12-10 14:27:09 +08:00

README.md

Modbus Master-Slave Example

Overview

These two projects illustrate the communication between Modbus master and slave device in the segment. Master initializes Modbus interface driver and then reads parameters from slave device in the segment. After several successful read attempts slave sets the alarm relay (end of test condition). Once master reads the alarm it stops communication and destroy driver.

The examples:

  • examples/protocols/modbus/serial/mb_master - Modbus serial master ASCII/RTU
  • examples/protocols/modbus/serial/mb_slave - Modbus serial slave ASCII/RTU

See README.md for each individual project for more information.

How to use example

Hardware Required

This example can be run on any commonly available ESP32 development board. The master and slave boards should be connected to each other through the RS485 interface line driver. See the connection schematic in README.md files of each example.

Configure the project

This example test requires communication mode setting for master and slave be the same and slave address set to 1. Please refer to README.md files of each example project for more information.

About common_component in this example

The folder "mb_example_common" includes definitions of parameter structures for master and slave device (both projects share the same parameters). However, currently it is for example purpose only and can be modified for particular application.

Example Output

Example of Slave output:

I (343) SLAVE_TEST: Modbus slave stack initialized.
I (343) SLAVE_TEST: Start modbus test...
I (81463) SLAVE_TEST: HOLDING READ (81150420 us), ADDR:1, TYPE:2, INST_ADDR:0x3ffb2868, SIZE:6
I (82463) SLAVE_TEST: HOLDING READ (82150720 us), ADDR:1, TYPE:2, INST_ADDR:0x3ffb2868, SIZE:6
I (83573) SLAVE_TEST: HOLDING READ (83260630 us), ADDR:1, TYPE:2, INST_ADDR:0x3ffb2868, SIZE:6
I (84603) SLAVE_TEST: HOLDING READ (84290530 us), ADDR:1, TYPE:2, INST_ADDR:0x3ffb2868, SIZE:6
I (85703) SLAVE_TEST: HOLDING READ (85396692 us), ADDR:1, TYPE:2, INST_ADDR:0x3ffb2868, SIZE:6

Example of Modbus Master output:

I (399) MASTER_TEST: Modbus master stack initialized...
I (499) MASTER_TEST: Start modbus test...
I (549) MASTER_TEST: Characteristic #0 Data_channel_0 (Volts) value = 1.230000 (0x3f9d70a4) read successful.
I (629) MASTER_TEST: Characteristic #1 Humidity_1 (%rH) value = 12.100000 (0x4141999a) read successful.
I (709) MASTER_TEST: Characteristic #2 Temperature_1 (C) value = 3.560000 (0x4063d70a) read successful.
I (769) MASTER_TEST: Characteristic #3 Humidity_2 (%rH) value = 23.400000 (0x41bb3333) read successful.
I (829) MASTER_TEST: Characteristic #4 Temperature_2 (C) value = 5.890000 (0x40bc7ae1) read successful.
I (889) MASTER_TEST: Characteristic #5 Humidity_3 (%rH) value = 34.500000 (0x420a0000) read successful.
E (949) MB_CONTROLLER_MASTER: mbc_master_get_parameter(111): SERIAL master get parameter failure error=(0x108) (ESP_ERR_INVALID_RESPONSE).
E (949) MASTER_TEST: Characteristic #6 (RelayP1) read fail, err = 264 (ESP_ERR_INVALID_RESPONSE).
E (1029) MB_CONTROLLER_MASTER: mbc_master_get_parameter(111): SERIAL master get parameter failure error=(0x108) (ESP_ERR_INVALID_RESPONSE).
E (1029) MASTER_TEST: Characteristic #7 (RelayP2) read fail, err = 264 (ESP_ERR_INVALID_RESPONSE).

Troubleshooting

If the examples do not work as expected and slave and master boards are not able to communicate correctly it is possible to find the reason for errors. The most important errors are described in master example output and formatted as below:

E (1692332) MB_CONTROLLER_MASTER: mbc_master_get_parameter(111): SERIAL master get parameter failure error=(0x107) (ESP_ERR_TIMEOUT).

ESP_ERR_TIMEOUT (0x107) - Modbus slave device does not respond during configured timeout. Check the connection and ability for communication using uart_echo_rs485 example or increase Kconfig value CONFIG_FMB_MASTER_TIMEOUT_MS_RESPOND (CONFIG_FMB_SERIAL_ASCII_TIMEOUT_RESPOND_MS).

ESP_ERR_NOT_SUPPORTED (0x106), ESP_ERR_INVALID_RESPONSE (0x108) - Modbus slave device does not support requested command or register and sent exeption response.

ESP_ERR_INVALID_STATE (0x103) - Modbus stack is not configured correctly or can't work correctly due to critical failure.