* Fix the issue that deinit node with "erase_flash"
set to true, but info is not erased from nvs
* Reuse bt_mesh_cfg_reset() when deinit node
* Optimize Provisioner related erase operations
* No store pending timeout will be used when Node
is not provisioned OR Provisioner is disabled
and erase operation is performed
* Change the default timeout for settings operation
to 0, and rpl store rate to 0
When reset the rx info of transport layer, the
rpl list will always cleared, and rpl stored
in the nvs will only be erased when erase flag
is true and BLE_MESH_SETTINGS is enabled.
Compared with the previous solution, it should
be more clear.
Provisioner should always uses the latest IV Index for provisioning.
For example, if the current IV Index is 0x00000001, but prov->iv_index
is still initialized with 0x00000000, and if Provisioner uses prov->
iv_index for provisioning, this will cause the Provisioner failing to
control the node.
So here bt_mesh.iv_index is used instead of prov->iv_index.
Currently only keep func pointer for the followings:
- Invalid parameter (mesh btc & mesh stack)
- Out of memory (mesh btc & mesh stack)
- Unknown act (mesh btc)
- Invalid model user data (mesh stack)
- BT_DBG("%s", __func__) (mesh btc & mesh stack)
- A few other specific situations (buf ref debug, send status check)
Old version of BLE Mesh has no device role storage, because
previously we only support storing mesh node info.
If the binary of the node is upgraded from old version to a
new version (support storing provisioner info), the mesh info
of the node will not be restored because mesh role does not
exist in the flash.
Previously only mesh node info is supported to be stored
in flash. So when trying to reset the node, we only need
to judge if the BLE_MESH_VALID flag is set.
Currently we support storing both node & Provisioner info
in flash, when trying to erase the node info from flash,
the BLE_MESH_NODE flag will be checked. So we need to set
bt_mesh.flags to 0 when all the erase operations are done.
During BLE Mesh Provisioner initialization, the stack will restore
the nodes information if settings storage is enabled.
Previously when a failure happens (e.g. found the same uuid) during
the restore procedure, the information of the following nodes will
not be restored and error will be directly returned.
But this will introduce some problem with user experience, because
some newly provisioned nodes information will not be restored and
Provisioner will not be able to control those nodes.
So we change the operation here, when a failure happens during the
restore procedure, Provisioner will only ignore the information of
the current node and continue restoring other nodes information.
Previously the BLE_MESH_MAX_STORED_NODES option is added for
internal mesh test, which will be a little confusing for the
users to understand.
Here we remove this option, instead the BLE_MESH_MAX_PROV_NODES
will be used for all the cases. For mesh internal test, when
the test function is called to add some nodes info, the info
will be stored in the array of provisioned nodes directly.
1. Add an API to set Provisioner static oob value
2. Add an API to deinit BLE Mesh stack
3. Add an API to set Provisioner unicast address
4. Add an API to provision devices with fixed address
5. Add an API to store node composition data
6. Add an API to get node with device uuid
7. Add an API to get node with unicast address
8. Add an API to delete node with device uuid
9. Add an API to delete node with unicast address
10. Add an API for Provisioner to update local AppKey
11. Add an API for Provisioner to update local NetKey
12. Support Provisioner persistent functionality
13. Fix Provisioner entering IV Update procedure
14. Fix an issue which may cause client failing to send msg
15. Use bt_mesh.flags to indicate device role
16. Remove several useless macros
17. Callback RSSI of received mesh provisioning packets
18. Modify the Provisioner disable function
19. Change some log level from debug to info
20. Add parameters to Provisioner bind AppKey completion event
21. Fix node ignoring relay messages issue
22. Support using a specific partition for BLE Mesh
23. Fix compile warning when proxy related macros are disabled
24. Clean up BLE Mesh stack included header files
25. NULL can be input if client message needs no parameters
26. Fix compile warning when BT log is disabled
27. Initilize BLE Mesh stack local variables
28. Support using PSRAM for BLE Mesh mutex, queue and task
29. Add a menuconfig option to enable using memory from PSRAM
30. Clean up sdkconfig.defaults of BLE Mesh examples
The 16-bit format group addresses will be stored,
but we don't store (or restore) the virtual label UUIDs,
i.e. after a power cycle the 16-bit group addresses
would be meaningless.