# Modbus Slave Example
|
||
|
|
||
|
This example demonstrates using of FreeModbus TCP slave stack port implementation for ESP32(-S2). The external Modbus host is able to read/write device parameters using Modbus protocol transport. The parameters accessible thorough Modbus are located in `mb_example_common/modbus_params.h\c` files and can be updated by user.
|
||
|
These are represented in structures holding_reg_params, input_reg_params, coil_reg_params, discrete_reg_params for holding registers, input parameters, coils and discrete inputs accordingly. The app_main application demonstrates how to setup Modbus stack and use notifications about parameters change from host system.
|
||
|
The FreeModbus stack located in `components/freemodbus` folder and contain `/port` folder inside which contains FreeModbus stack port for ESP32. There are some parameters that can be configured in KConfig file to start stack correctly (See description below for more information).
|
||
|
|
||
|
The slave example uses shared parameter structures defined in ```examples/protocols/modbus/mb_example_common``` folder.
|
||
|
|
||
|
## Hardware required :
|
||
|
Option 1:
|
||
|
The ESP32(-S2) development board flashed with modbus_tcp_slave example + external Modbus master host software.
|
||
|
|
||
|
Option 2:
|
||
|
The modbus_tcp_master example application configured as described in its README.md file and flashed into ESP32(-S2) board.
|
||
|
Note: The ```Example Data (Object) Dictionary``` in the modbus_tcp_master example can be edited to address parameters from other slaves connected into Modbus segment.
|
||
|
|
||
|
## How to setup and use an example:
|
||
|
|
||
|
### Configure the application
|
||
|
Start the command below to show the configuration menu:
|
||
|
```
|
||
|
idf.py menuconfig
|
||
|
```
|
||
|
|
||
|
To configure the example to use Wi-Fi or Ethernet connection, open the project configuration menu and navigate to "Example Connection Configuration" menu. Select either "Wi-Fi" or "Ethernet" in the "Connect using" choice.
|
||
|
Follow the instructions in `examples/common_components/protocol_examples_common` for further configuration.
|
||
|
|
||
|
The communication parameters of freemodbus stack (Component config->Modbus configuration) allow to configure it appropriately but usually it is enough to use default settings.
|
||
|
See the help strings of parameters for more information.
|
||
|
|
||
|
### Setup external Modbus master software
|
||
|
Option 1:
|
||
|
Configure the external Modbus master software according to port configuration parameters used in application.
|
||
|
As an example the Modbus Poll application can be used with this example.
|
||
|
Option 2:
|
||
|
Setup ESP32(-S2) development board and set modbus_tcp_master example configuration as described in its README.md file.
|
||
|
Setup one or more slave boards and connect them into the same Modbus segment (See configuration above).
|
||
|
|
||
|
### Build and flash software
|
||
|
Build the project and flash it to the board, then run monitor tool to view serial output:
|
||
|
```
|
||
|
idf.py -p PORT flash monitor
|
||
|
```
|
||
|
|
||
|
(To exit the serial monitor, type ``Ctrl-]``.)
|
||
|
|
||
|
See the Getting Started Guide for full steps to configure and use ESP-IDF to build projects.
|
||
|
|
||
|
## Example Output
|
||
|
Example output of the application:
|
||
|
```
|
||
|
I (4235) esp_netif_handlers: example_connect: sta ip: 192.168.1.21, mask: 255.255.255.0, gw: 192.168.1.1
|
||
|
I (4235) example_connect: Got IPv4 event: Interface "example_connect: sta" address: 192.168.1.21
|
||
|
I (4465) example_connect: Got IPv6 event: Interface "example_connect: sta" address: fe80:0000:0000:0000:7edf:a1ff:fe00:4039, type: ESP_IP6_ADDR_IS_LINK_LOCAL
|
||
|
I (4465) example_connect: Connected to example_connect: sta
|
||
|
I (4475) example_connect: - IPv4 address: 192.168.1.21
|
||
|
I (4475) example_connect: - IPv6 address: fe80:0000:0000:0000:7edf:a1ff:fe00:4039, type: ESP_IP6_ADDR_IS_LINK_LOCAL
|
||
|
I (4495) MB_TCP_SLAVE_PORT: Socket (#54), listener on port: 502, errno=0
|
||
|
I (4495) MB_TCP_SLAVE_PORT: Protocol stack initialized.
|
||
|
I (4505) SLAVE_TEST: Modbus slave stack initialized.
|
||
|
I (4505) SLAVE_TEST: Start modbus test...
|
||
|
I (41035) MB_TCP_SLAVE_PORT: Socket (#55), accept client connection from address: 192.168.1.39
|
||
|
I (41225) SLAVE_TEST: INPUT READ (41704766 us), ADDR:1, TYPE:8, INST_ADDR:0x3ffcb878, SIZE:2
|
||
|
I (41235) SLAVE_TEST: HOLDING READ (41719746 us), ADDR:1, TYPE:2, INST_ADDR:0x3ffcb9b4, SIZE:2
|
||
|
I (41255) SLAVE_TEST: INPUT READ (41732965 us), ADDR:3, TYPE:8, INST_ADDR:0x3ffcb87c, SIZE:2
|
||
|
I (41265) SLAVE_TEST: HOLDING READ (41745923 us), ADDR:3, TYPE:2, INST_ADDR:0x3ffcb9b8, SIZE:2
|
||
|
I (41275) SLAVE_TEST: INPUT READ (41759563 us), ADDR:5, TYPE:8, INST_ADDR:0x3ffcb880, SIZE:2
|
||
|
I (41295) SLAVE_TEST: HOLDING READ (41772568 us), ADDR:5, TYPE:2, INST_ADDR:0x3ffcb9bc, SIZE:2
|
||
|
I (41305) SLAVE_TEST: COILS WRITE (41785889 us), ADDR:0, TYPE:16, INST_ADDR:0x3ffcb874, SIZE:8
|
||
|
I (41315) SLAVE_TEST: COILS WRITE (41799175 us), ADDR:8, TYPE:16, INST_ADDR:0x3ffcb875, SIZE:8
|
||
|
I (41945) SLAVE_TEST: INPUT READ (42421629 us), ADDR:1, TYPE:8, INST_ADDR:0x3ffcb878, SIZE:2
|
||
|
I (42145) SLAVE_TEST: HOLDING READ (42626497 us), ADDR:1, TYPE:2, INST_ADDR:0x3ffcb9b4, SIZE:2
|
||
|
I (42345) SLAVE_TEST: INPUT READ (42831315 us), ADDR:3, TYPE:8, INST_ADDR:0x3ffcb87c, SIZE:2
|
||
|
I (42555) SLAVE_TEST: HOLDING READ (43036111 us), ADDR:3, TYPE:2, INST_ADDR:0x3ffcb9b8, SIZE:2
|
||
|
I (42755) SLAVE_TEST: INPUT READ (43240950 us), ADDR:5, TYPE:8, INST_ADDR:0x3ffcb880, SIZE:2
|
||
|
I (42865) SLAVE_TEST: HOLDING READ (43343204 us), ADDR:5, TYPE:2, INST_ADDR:0x3ffcb9bc, SIZE:2
|
||
|
......
|
||
|
I (81265) SLAVE_TEST: HOLDING READ (81743698 us), ADDR:5, TYPE:2, INST_ADDR:0x3ffcb9bc, SIZE:2
|
||
|
I (81465) SLAVE_TEST: COILS WRITE (81948482 us), ADDR:0, TYPE:16, INST_ADDR:0x3ffcb874, SIZE:8
|
||
|
I (81465) SLAVE_TEST: Modbus controller destroyed.
|
||
|
```
|
||
|
The output lines describe type of operation, its timestamp, modbus address, access type, storage address in parameter structure and number of registers accordingly.
|
||
|
|