/** \page xmlrpc_control_page Xmlrpc Control \tableofcontents XML-RPC data is transported via simple HTTP and client implementations exist for most programming languages. A Perl client that can be used as a control script is included in the source tar ball as scripts/fldigi-shell. This control method is currently used by several external programs including flrig, logger32 and Xlog. The following command line arguments become available when XML-RPC support is compiled into fldigi, as described in the \ref install_from_source_page "build instructions": \verbatim --xmlrpc-server-address HOSTNAME Set the XML-RPC server address. The default is 127.0.0.1. --xmlrpc-server-port PORT Set the XML-RPC server port. The default is 7362. --xmlrpc-allow REGEX Allow only the methods whose names match REGEX --xmlrpc-deny REGEX Allow only the methods whose names don't match REGEX --xmlrpc-list List all available methods \endverbatim The --xmlrpc-deny and --xmlrpc-allow switches can be used as a simple access control mechanism. REGEX specifies a POSIX extended regular expression. This invocation disables the methods that may cause fldigi to transmit: \verbatim --xmlrpc-deny 'main\.(tx|tune|run_macro)' \endverbatim By default all methods are allowed. The --xmlrpc-list switch outputs the method list and exits the program. If preceded by --xmlrpc-deny or --xmlrpc-allow, it shows the list of methods as filtered by those switches. The methods are listed below. The three columns are method name, signature (return_type:argument_types), and description. Refer to the XML-RPC specification for the meaning of the signature characters \latexonly \pagebreak \endlatexonly \section sub_symbol_interpretation XML Command Symbol Interpretation
Symbol | Interpretation :------:|:---: n | nil b | boolean i | integer d | double s | string 6 | bytes A | array S | struct
\section sub_xml_commands Table of XML Commands
Method Name | Sig (ret:arg) | Description :---------- |:---:|:----------- fldigi.list | A:n | Returns the list of methods fldigi.name | s:n | Returns the program name fldigi.version_struct | S:n | Returns the program version as a struct fldigi.version | s:n | Returns the program version as a string fldigi.name_version | s:n | Returns the program name and version fldigi.config_dir | s:n | Returns the name of the configuration directory fldigi.terminate | n:i | Terminates fldigi. ``i'' is bitmask specifying data to save: 0=options; 1=log; 2=macros modem.get_name | s:n | Returns the name of the current modem modem.get_names | A:n | Returns all modem names modem.get_id | i:n | Returns the ID of the current modem modem.get_max_id | i:n | Returns the maximum modem ID number modem.set_by_name | s:s | Sets the current modem. Returns old name modem.set_by_id | i:i | Sets the current modem. Returns old ID modem.set_carrier | i:i | Sets modem carrier. Returns old carrier modem.inc_carrier | i:i | Increments the modem carrier frequency. Returns the new carrier modem.get_carrier | i:n | Returns the modem carrier frequency modem.get_afc_search_range | i:n | Returns the modem AFC search range modem.set_afc_search_range | n:i | Sets the modem AFC search range. Returns the old value modem.inc_afc_search_range | n:i | Increments the modem AFC search range. Returns the new value modem.get_bandwidth | i:n | Returns the modem bandwidth modem.set_bandwidth | n:i | Sets the modem bandwidth. Returns the old value modem.inc_bandwidth | n:i | Increments the modem bandwidth. Returns the new value modem.get_quality | d:n | Returns the modem signal quality in the range [0:100] modem.search_up | n:n | Searches upward in frequency modem.search_down | n:n | Searches downward in frequency modem.olivia.set_bandwidth | n:i | Sets the Olivia bandwidth modem.olivia.get_bandwidth | i:n | Returns the Olivia bandwidth modem.olivia.set_tones | n:i | Sets the Olivia tones modem.olivia.get_tones | i:n | Returns the Olivia tones main.get_status1 | s:n | Returns the contents of the first status field (typically s/n) main.get_status2 | s:n | Returns the contents of the second status field main.get_wf_sideband | s:n | Returns the current waterfall sideband main.set_wf_sideband | n:s | Sets the waterfall sideband to USB or LSB main.get_frequency | d:n | Returns the RF carrier frequency main.set_frequency | d:d | Sets the RF carrier frequency. Returns the old value main.inc_frequency | d:d | Increments the RF carrier frequency. Returns the new value main.get_afc | b:n | Returns the AFC state main.set_afc | b:b | Sets the AFC state. Returns the old state main.toggle_afc | b:n | Toggles the AFC state. Returns the new state main.get_squelch | b:n | Returns the squelch state main.set_squelch | b:b | Sets the squelch state. Returns the old state main.toggle_squelch | b:n | Toggles the squelch state. Returns the new state main.get_squelch_level | d:n | Returns the squelch level main.set_squelch_level | d:d | Sets the squelch level. Returns the old level main.inc_squelch_level | d:d | Increments the squelch level. Returns the new level main.get_reverse | b:n | Returns the Reverse Sideband state main.set_reverse | b:b | Sets the Reverse Sideband state. Returns the old state main.toggle_reverse | b:n | Toggles the Reverse Sideband state. Returns the new state main.get_lock | b:n | Returns the Transmit Lock state main.set_lock | b:b | Sets the Transmit Lock state. Returns the old state main.toggle_lock | b:n | Toggles the Transmit Lock state. Returns the new state main.get_rsid | b:n | Returns the RSID state main.set_rsid | b:b | Sets the RSID state. Returns the old state main.toggle_rsid | b:n | Toggles the RSID state. Returns the new state main.get_trx_status | s:n | Returns transmit/tune/receive status main.rx | n:n | Receives main.tx | n:n | Transmits main.tune | n:n | Tunes main.abort | n:n | Aborts a transmit or tune main.get_trx_state | s:n | Returns T/R state main.run_macro | n:i | Runs a macro main.get_max_macro_id | i:n | Returns the maximum macro ID number rig.set_name | n:s | Sets the rig name for xmlrpc rig rig.get_name | s:n | Returns the rig name previously set via rig.set_name rig.set_frequency | d:d | Sets the RF carrier frequency. Returns the old value rig.set_modes | n:A | Sets the list of available rig modes rig.set_mode | n:s | Selects a mode previously added by rig.set_modes rig.get_modes | A:n | Returns the list of available rig modes rig.get_mode | s:n | Returns the name of the current transceiver mode rig.set_bandwidths | n:A | Sets the list of available rig bandwidths rig.set_bandwidth | n:s | Selects a bandwidth previously added by rig.set_bandwidths rig.get_bandwidth | s:n | Returns the name of the current transceiver bandwidth rig.get_bandwidths | A:n | Returns the list of available rig bandwidths rig.take_control | n:n | Switches rig control to XML-RPC rig.release_control | n:n | Switches rig control to previous setting log.get_frequency | s:n | Returns the Frequency field contents log.get_time_on | s:n | Returns the Time-On field contents log.get_time_off | s:n | Returns the Time-Off field contents log.get_call | s:n | Returns the Call field contents log.get_name | s:n | Returns the Name field contents log.get_rst_in | s:n | Returns the RST(r) field contents log.get_rst_out | s:n | Returns the RST(s) field contents log.get_serial_number | s:n | Returns the serial number field contents log.set_serial_number | n:s | Sets the serial number field contents log.get_serial_number_sent | s:n | Returns the serial number (sent) field contents log.get_exchange | s:n | Returns the contest exchange field contents log.set_exchange | n:s | Sets the contest exchange field contents log.get_state | s:n | Returns the State field contents log.get_province | s:n | Returns the Province field contents log.get_country | s:n | Returns the Country field contents log.get_qth | s:n | Returns the QTH field contents log.get_band | s:n | Returns the current band name log.get_notes | s:n | Returns the Notes field contents log.get_locator | s:n | Returns the Locator field contents log.get_az | s:n | Returns the AZ field contents log.clear | n:n | Clears the contents of the log fields log.set_call | n:s | Sets the Call field contents log.set_name | n:s | Sets the Name field contents log.set_qth | n:s | Sets the QTH field contents log.set_locator | n:s | Sets the Locator field contents text.get_rx_length | i:n | Returns the number of characters in the RX widget text.get_rx | 6:ii | Returns a range of characters (start, length) from the RX text widget text.clear_rx | n:n | Clears the RX text widget text.add_tx | n:s | Adds a string to the TX text widget text.add_tx_bytes | n:6 | Adds a byte string to the TX text widget text.clear_tx | n:n | Clears the TX text widget spot.get_auto | b:n | Returns the autospotter state spot.set_auto | n:b | Sets the autospotter state. Returns the old state spot.toggle_auto | n:b | Toggles the autospotter state. Returns the new state spot.pskrep.get_count | i:n | Returns the number of callsigns spotted in the current session
Deprecated methods:
Method Name | Sig | Resolution :---------- |:---:|:----------- main.get_sideband | s:n | use main.get_wf_sideband and/or rig.get_mode main.set_sideband | n:s | use main.set_wf_sideband and/or rig.set_mode main.rsid | n:n | use main.{get,set,toggle}_rsid main.set_rig_name | n:s | use rig.set_name main.set_rig_frequency | d:d | use rig.set_frequency main.set_rig_modes | n:A | use rig.set_modes main.set_rig_mode | n:s | use rig.set_mode main.get_rig_modes | A:n | use rig.get_modes main.get_rig_mode | s:n | use rig.get_mode main.set_rig_bandwidths | n:A | use rig.set_bandwidths main.set_rig_bandwidth | n:s | use rig.set_bandwidth main.get_rig_bandwidth | s:n | use rig.get_bandwidth main.get_rig_bandwidths | n:A | use rig.get_bandwidths log.get_sideband | s:n | use main.get_wf_sideband

\section sub_minimized_window Minimized WF Window
If your external control program duplicates some of the fldigi controls such as the Rx and Tx pane you can run fldigi in a fully minimized mode. Fldigi then only provides the controls necessary for signal acquisition and waterfall management. Minimization is accomplished by setting the command line switch ( --wo). The user interface then has this appearance: \image html UI-minimized.png "Simplified WF Window Display" \image latex UI-minimized.png "Simplified WF Window Display" width=5.0in The documentation for the external control program will provide additional information if this user interface is desired.
\ref xmlrpc_control_page "Return to Top of Page"
\ref main_page "Return to Main Page" */