a69dcfc49d
Avoid buffer overflows with longer mqtt topics mqtDeviceTopic in wled.h is defined with a size of 33, so this should be set to 45 to accommodate the additional 12 characters - /temperature |
||
---|---|---|
.. | ||
platformio_override.ini | ||
readme.md | ||
usermod_temperature.h | ||
usermods_list.cpp |
readme.md
Temperature usermod
Based on the excellent QuinLED_Dig_Uno_Temp_MQTT
by srg74 and 400killer!
This usermod will read from an attached DS18B20 temperature sensor (as available on the QuinLED Dig-Uno)
The temperature is displayed both in the Info section of the web UI as well as published to the /temperature
MQTT topic if enabled.
This usermod will be expanded with support for different sensor types in the future.
If temperature sensor is not detected during boot, this usermod will be disabled.
Installation
Copy the example platformio_override.ini
to the root directory. This file should be placed in the same directory as platformio.ini
.
Define Your Options
USERMOD_DALLASTEMPERATURE
- define this to have this user mod included wled00\usermods_list.cppUSERMOD_DALLASTEMPERATURE_CELSIUS
- define this to report temperatures in degrees celsious, otherwise fahrenheit will be reportedUSERMOD_DALLASTEMPERATURE_MEASUREMENT_INTERVAL
- the number of milliseconds between measurements, defaults to 60 secondsUSERMOD_DALLASTEMPERATURE_FIRST_MEASUREMENT_AT
- the number of milliseconds after boot to take first measurement, defaults to 20 seconds
Project link
- QuinLED-Dig-Uno - Project link
PlatformIO requirements
If you are using platformio_override.ini
, you should be able to refresh the task list and see your custom task, for example env:d1_mini_usermod_dallas_temperature_C
.
If you are not using platformio_override.ini
, you might have to uncomment DallasTemperature@~3.8.0
,OneWire@~2.3.5 under
[common]
section in platformio.ini
:
# platformio.ini
...
[platformio]
...
; default_envs = esp07
default_envs = d1_mini
...
[common]
...
lib_deps =
...
#For use SSD1306 OLED display uncomment following
U8g2@~2.27.3
#For Dallas sensor uncomment following 2 lines
DallasTemperature@~3.8.0
OneWire@~2.3.5
...
Change Log
2020-09-12
- Changed to use async, non-blocking implementation
- Do not report low temperatures that indicate an error to mqtt
- Disable plugin if temperature sensor not detected
- Report the number of seconds until the first read in the info screen instead of sensor error