Si4463/WDSSrc/application/si4463_revb1_varlenOKempty_...

497 wiersze
24 KiB
XML

<?xml version="1.0" encoding="windows-1251"?>
<RCA_ProjectData ProjectName="Empty framework" ChipType="Si4463" ChipRevision="B1" Version="3.2.6.0">
<DataItems>
<tbpFrequencyAndPower Type="System.Windows.Forms.TabPage">
<grbPowerAmplifierControl Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbEnablePaExternalRamp">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudPaRampTC">
<Value>29</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbPaMode">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudPaPowerLevel">
<Value>127</Value>
</DataItem>
</grbPowerAmplifierControl>
<grbCrystalControl Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbUseExternalTCXO">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudCrystalToleranceTX">
<Value>20</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudCrystalToleranceRX">
<Value>20</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudCrystalFrequency">
<Value>26</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudCrystalCapBank">
<Value>82</Value>
</DataItem>
</grbCrystalControl>
<grbFequencyControl Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudChannelNumber">
<Value>0</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudCenterFrequency">
<Value>437.92</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudChannelSpacing">
<Value>250</Value>
</DataItem>
</grbFequencyControl>
</tbpFrequencyAndPower>
<tbpRfParameters Type="System.Windows.Forms.TabPage">
<grbRfParameters Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbModulationType">
<SelectedIndex>1</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudDataRate">
<Value>1</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudDeviation">
<Value>2</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbManualRxBandwidth">
<Checked>True</Checked>
</DataItem>
<DataItem Type="NewWDS.Applications.App_Common.CustomContols.NumericUpDownExtended" Name="nudBandwidth">
<Value>4</Value>
</DataItem>
<pnlRssiControl Type="System.Windows.Forms.Panel">
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbRssiLatch">
<SelectedIndex>2</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudRssiJumpTheshold">
<Value>12</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbRssiAverage">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudRssiThreshold">
<Value>255</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbCheckThresholdAtLatch">
<Checked>False</Checked>
</DataItem>
</pnlRssiControl>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbEnableHighPerformanceChannelFilter">
<Checked>True</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbEnableAntennaDiversity">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbEnableIqCalibration">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbEnablePllAFC">
<Checked>True</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbEnableAdaptiveChannelFilterBandwidth">
<Checked>True</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbIfMode">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbPreamblePattern">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbDataRateError">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<grbHighPerformance Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbLowPower">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbHighPerformance">
<Checked>True</Checked>
</DataItem>
</grbHighPerformance>
</grbRfParameters>
</tbpRfParameters>
<tbpPacketHandler Type="System.Windows.Forms.TabPage">
<pccPacketHandlerConfigurator Type="NewWDS.PacketConfigControl">
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbPacketStructure">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<tabGeneralConfig Type="System.Windows.Forms.TabControl">
<tbpGeneralPacketConfig Type="System.Windows.Forms.TabPage">
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudPacketRxThreshold">
<Value>48</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudPacketTxThreshold">
<Value>48</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudNumOfFields">
<Value>2</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbResetDataWhiteningAtBeginingOfThePackets">
<Checked>True</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbUseSyncWord">
<Checked>True</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbUsePreambel">
<Checked>True</Checked>
</DataItem>
</tbpGeneralPacketConfig>
<tbpVariableLengthConfig Type="System.Windows.Forms.TabPage">
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbEnableVariablePacketLength">
<Checked>True</Checked>
</DataItem>
<grbVariablePacketLen Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudPacketLengthAdjust">
<Value>0</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudVariableFieldNum">
<Value>2</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudLengthInField">
<Value>1</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbPacketLengthInMsb">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbAddLengthToFifo">
<Checked>False</Checked>
</DataItem>
</grbVariablePacketLen>
</tbpVariableLengthConfig>
<tbpGeneralCrcConfig Type="System.Windows.Forms.TabPage">
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbResetCRCAtBeginingOfThePacket">
<Checked>True</Checked>
</DataItem>
<grbCrcPolynomial Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbCrcPolynomial">
<SelectedIndex>4</SelectedIndex>
</DataItem>
</grbCrcPolynomial>
<grbCrcSeed Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbCrcSeed1">
<Checked>True</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbCrcSeed0">
<Checked>False</Checked>
</DataItem>
</grbCrcSeed>
</tbpGeneralCrcConfig>
<tbpGeneralFieldConfig Type="System.Windows.Forms.TabPage">
<grbCrcEndian Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbHighBytesFirst">
<Checked>True</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbLowBytesFirst">
<Checked>False</Checked>
</DataItem>
</grbCrcEndian>
<grbBitOrder Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbLsbFirst">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbMsbFirst">
<Checked>True</Checked>
</DataItem>
</grbBitOrder>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbInvertCrc">
<Checked>False</Checked>
</DataItem>
<grbManchesterPattern Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdb0eqs01">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdb0eqs10">
<Checked>True</Checked>
</DataItem>
</grbManchesterPattern>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbRxChainOnAfterRx">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbModem4Gfsk">
<Checked>False</Checked>
</DataItem>
</tbpGeneralFieldConfig>
</tabGeneralConfig>
<tabFieldConfig Type="NewWDS.CustomTablessTabControl">
<tbpPreamble Type="System.Windows.Forms.TabPage">
<grbPreamble Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.TrackBar" Name="trbPreambleTimeot">
<Value>15</Value>
</DataItem>
<grbPreambleType Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbPreambleTypeCustom">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbPreambleType0101">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbPreambleType1010">
<Checked>True</Checked>
</DataItem>
</grbPreambleType>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbPreambleManchesterEncoded">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudPreambleRXThreshold">
<Value>20</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudPreambleTxLength">
<Value>8</Value>
</DataItem>
</grbPreamble>
</tbpPreamble>
<tbpSyncWord Type="System.Windows.Forms.TabPage">
<grbSyncWord Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudSyncWordLength">
<Value>2</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.MaskedTextBox" Name="mtbSyncWord">
<Text>2D D4</Text>
</DataItem>
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudSyncWordAllowedBitError">
<Value>0</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbSyncWordManchesterEncoded">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbSkipSyncWordTimeout">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbSyncWord4GfskModulated">
<Checked>False</Checked>
</DataItem>
</grbSyncWord>
</tbpSyncWord>
<tbpField2 Type="System.Windows.Forms.TabPage">
<grbField2 Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudField2Length">
<Value>59</Value>
</DataItem>
<haiField2Content Type="NewWDS.Applications.App_Common.PacketConfigControl.HexAsciiInputControl">
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbASCII">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.RadioButton" Name="rdbHEX">
<Checked>True</Checked>
</DataItem>
<pnlInput Type="System.Windows.Forms.Panel">
<DataItem Type="System.Windows.Forms.MaskedTextBox" Name="mtbInput">
<Text>C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5 C5</Text>
</DataItem>
</pnlInput>
</haiField2Content>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField2EnableCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField2CheckCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField2TransmitCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField2DataWhitening">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField2ManchesterEncoding">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField24GfskModulated">
<Checked>False</Checked>
</DataItem>
</grbField2>
</tbpField2>
<tbpField5 Type="System.Windows.Forms.TabPage">
<grbField5 Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudField5Length">
<Value>7</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField5EnableCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField5CheckCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField5TransmitCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField5DataWhitening">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField5ManchesterEncoding">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField54GfskModulated">
<Checked>False</Checked>
</DataItem>
</grbField5>
</tbpField5>
<tbpField4 Type="System.Windows.Forms.TabPage">
<grbField4 Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudField4Length">
<Value>7</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField4EnableCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField4CheckCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField4TransmitCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField4DataWhitening">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField4ManchesterEncoding">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField44GfskModulated">
<Checked>False</Checked>
</DataItem>
</grbField4>
</tbpField4>
<tbpField3 Type="System.Windows.Forms.TabPage">
<grbField3 Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudField3Length">
<Value>7</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField3EnableCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField3CheckCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField3TransmitCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField3DataWhitening">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField3ManchesterEncoding">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField34GfskModulated">
<Checked>False</Checked>
</DataItem>
</grbField3>
</tbpField3>
<tbpField1 Type="System.Windows.Forms.TabPage">
<grbField1 Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.NumericUpDown" Name="nudField1Length">
<Value>1</Value>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField1TransmitCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField1CheckCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField1EnableCRC">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField1DataWhitening">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField1ManchesterEncoding">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbField14GfskModulated">
<Checked>False</Checked>
</DataItem>
</grbField1>
</tbpField1>
</tabFieldConfig>
</pccPacketHandlerConfigurator>
</tbpPacketHandler>
<tbpInterrupts Type="System.Windows.Forms.TabPage">
<grbChipInterrupt Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbEnableChipInterrupt">
<Checked>False</Checked>
</DataItem>
<DataItem Type="NewWDS.Applications.App_Common.ByteStatusControl.ByteStatus" Name="bstChipInterruptStatus">
<Enabled>False</Enabled>
<Value>0</Value>
</DataItem>
</grbChipInterrupt>
<grbModemInterrupt Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbEnableModemInterrupt">
<Checked>False</Checked>
</DataItem>
<DataItem Type="NewWDS.Applications.App_Common.ByteStatusControl.ByteStatus" Name="bstModemInterruptStatus">
<Enabled>False</Enabled>
<Value>0</Value>
</DataItem>
</grbModemInterrupt>
<grbPacketHandlerInterrupt Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbEnablePacketHandlerInterrupt">
<Checked>True</Checked>
</DataItem>
<DataItem Type="NewWDS.Applications.App_Common.ByteStatusControl.ByteStatus" Name="bstPacketHandlerInterruptStatus">
<Enabled>True</Enabled>
<Value>56</Value>
</DataItem>
</grbPacketHandlerInterrupt>
<grbColorDescrition Type="System.Windows.Forms.GroupBox" />
</tbpInterrupts>
<tbpGPIO Type="System.Windows.Forms.TabPage">
<grbFastResponseRegisters Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbFrrA">
<SelectedIndex>10</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbFrrC">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbFrrD">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbFrrB">
<SelectedIndex>4</SelectedIndex>
</DataItem>
</grbFastResponseRegisters>
<grbGPIO Type="System.Windows.Forms.GroupBox">
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbDriveStrength">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbSdoPullup">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbGpio2">
<SelectedIndex>27</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbNirqPullup">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbGpio3">
<SelectedIndex>28</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbGpio3Pullup">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbGpio1">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbGpio2Pullup">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbGpio1Pullup">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbGpio0">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.CheckBox" Name="chbGpio0Pullup">
<Checked>False</Checked>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbNirq">
<SelectedIndex>0</SelectedIndex>
</DataItem>
<DataItem Type="System.Windows.Forms.ComboBox" Name="cbbSdo">
<SelectedIndex>0</SelectedIndex>
</DataItem>
</grbGPIO>
</tbpGPIO>
</DataItems>
</RCA_ProjectData>