DF8OEs investigations about sensor access ------------------------------------------ Temperature and humidity sensor directly goes to STM. There is no interface chip to handle them - all is done by software. Pinout of sensor boom: ---------------------- 1 - GND 2 - temperature sensor (1) 3 - GND 4 - humidity sensor1 (1) 5 - GND 6 - humidity sensor1 (2) 7 - GND 8 - heater humidity sensor 9 - heater humidity sensor 10 - GND 11 - humidity sensor2 (1) 12 - GND 13 - temperature sensor (2) and humidity sensor2 (2) 14 - GND 15 - GND 16 - GND 17 - GND 18 - GND 19 - GND 20 - GND Counted from left to right if you position flexsensor in front of you, pins near to you, sensor away from you, copper upside All connections leading to sensor boom do have corresponding test points on PCB: -------------------------------------------------------------------------------- Position PCB in front of you, flatconnector upside, sensor boom showing away from you, TX antenna leading to you. I draw connector as a row of "+++". Testpoints are small round copper isles (numbers correspond to sensor boom, G == GND, ? == unknown): 11 +++++++++++++++++++++++ G 4 8 6 2 13 ? 9 Investigations about temperature sensor: ---------------------------------------- Temperature sensor is resistance-based. If you insert a resistor between pin2 and pin13 of flatconnector, the following telemetry is transmitted: 330R --> -168° 560R --> -113° 820R --> -52° 1K --> -4.1° 1.5K --> 121° 2.2K --> 319° Pressure sensor module: ----------------------- This module is connected to SPI2 of STM. It uses SPI_NSS and only data output from module - SPI output from STM is not connected to module. So I think it is a kind of polling. 2 be continued