Supply voltage can be applied either by miniUSB connector or +5V pin in right header. Use both metods are not allowed and
|
|
can lead even to burning controler and/or power supply.
|
|
|
|
PC3 - PTT (default Open Drain)
|
|
PA4 - DAC Output - signal from controller to radio
|
|
PC1 - ADC input - signal from radio to controller. Schould be connected via 100nF in series capacitor and 10k-10k voltage
|
|
divider to apply 1.65V (half od 3.3V) bias on ADC input
|
|
|
|
PA10 - UART RX
|
|
PA9 - UART TX - This UART port of course work in TTL3.3V logic levels so You need MAX3232 or simmilar to connect to PC
|
|
|
|
PB6 - SCL to i2c pressure sensor
|
|
PB7 - SDA to i2c pressure sensor
|
|
|
|
PB9 - TX line from TX20 anemometr - brown wire in original cable
|
|
PB8 - DTR line from TX20 aneometr - green wire in original cable but it can be just permanently
|
|
pulled down do ground via 1k resistor (ground is yellow wire in original cable).
|
|
tx20 anemometr should be powered from positive 5V voltage
|
|
|
|
|
|
PC6 - Dallas One Wire pin to DS termometer. Only one termometer can be used and it should be powered via separate +5V line,
|
|
parasite power is not recommended.
|
|
|
|
PC4 - DHT22 pin
|
|
|
|
LEDS:
|
|
Blue LED - DCD - lights up while controller is receiving APRS packet from radio.
|
|
Green LED - If meteo is enabled this blinks when transmission from TX20 anemometr is correctly received.
|
|
In 'non-meteo' mode it works as TX indicator and lights up when controler is transmitting data.
|
|
|
|
|