2020-08-26 19:57:35 +00:00
|
|
|
#include "drivers/bmp280/bmp280.h"
|
|
|
|
#include "bmp280_handler.h"
|
2022-02-27 13:45:10 +00:00
|
|
|
#include "log.h"
|
2020-08-26 19:57:35 +00:00
|
|
|
|
|
|
|
bmp280 bmp280_dev;
|
|
|
|
|
2022-02-27 13:45:10 +00:00
|
|
|
static bool bmp280_initialization_required = true;
|
|
|
|
|
2020-08-26 19:57:35 +00:00
|
|
|
bool bmp280_handler_init()
|
|
|
|
{
|
|
|
|
bmp280_dev.port = &DEFAULT_I2C_PORT;
|
|
|
|
bmp280_dev.addr = BMP280_I2C_ADDRESS_1;
|
|
|
|
|
|
|
|
bmp280_params_t bmp280_params = {
|
|
|
|
.mode = BMP280_MODE_NORMAL,
|
|
|
|
.filter = BMP280_FILTER_16,
|
|
|
|
.oversampling_pressure = BMP280_ULTRA_HIGH_RES,
|
|
|
|
.oversampling_temperature = BMP280_ULTRA_HIGH_RES,
|
|
|
|
.oversampling_humidity = BMP280_ULTRA_HIGH_RES,
|
|
|
|
.standby = BMP280_STANDBY_250,
|
|
|
|
};
|
|
|
|
|
2022-02-27 13:45:10 +00:00
|
|
|
bool success = bmp280_init(&bmp280_dev, &bmp280_params);
|
|
|
|
bmp280_initialization_required = !success;
|
|
|
|
return success;
|
2020-08-26 19:57:35 +00:00
|
|
|
}
|
|
|
|
|
|
|
|
bool bmp280_read(int32_t *temperature_celsius_100, uint32_t *pressure_mbar_100, uint32_t *humidity_percentage_100)
|
|
|
|
{
|
|
|
|
int32_t temperature_raw;
|
|
|
|
uint32_t pressure_raw;
|
|
|
|
uint32_t humidity_raw;
|
|
|
|
|
|
|
|
bool success = bmp280_read_fixed(&bmp280_dev, &temperature_raw, &pressure_raw, &humidity_raw);
|
|
|
|
if (!success) {
|
2022-02-27 13:45:10 +00:00
|
|
|
log_error("BMP280 read failed\n");
|
2020-08-26 19:57:35 +00:00
|
|
|
return false;
|
|
|
|
}
|
|
|
|
|
|
|
|
if (temperature_celsius_100) {
|
|
|
|
*temperature_celsius_100 = temperature_raw;
|
|
|
|
}
|
|
|
|
if (pressure_mbar_100) {
|
2021-11-16 08:11:54 +00:00
|
|
|
// Pressure unit is Pascal (= mbar * 100) * 256
|
|
|
|
*pressure_mbar_100 = (uint32_t) (((float) pressure_raw) / 256.0f);
|
2020-08-26 19:57:35 +00:00
|
|
|
}
|
2022-02-27 13:45:10 +00:00
|
|
|
// NOTE: Only BME280 sensors will report humidity. For BMP280 humidity readings will be zero.
|
2020-08-26 19:57:35 +00:00
|
|
|
if (humidity_percentage_100) {
|
|
|
|
*humidity_percentage_100 = (uint32_t) (((float) humidity_raw) * 100.0f / 1024.0f);
|
|
|
|
}
|
|
|
|
|
|
|
|
return true;
|
|
|
|
}
|
|
|
|
|
|
|
|
bool bmp280_read_telemetry(telemetry_data *data)
|
|
|
|
{
|
2022-02-27 13:45:10 +00:00
|
|
|
bool success;
|
|
|
|
|
|
|
|
if (bmp280_initialization_required) {
|
|
|
|
log_info("BMP280 re-init\n");
|
|
|
|
success = bmp280_handler_init();
|
|
|
|
log_info("BMP280 re-init: %d\n", success);
|
|
|
|
if (!success) {
|
|
|
|
data->temperature_celsius_100 = 0;
|
|
|
|
data->pressure_mbar_100 = 0;
|
|
|
|
data->humidity_percentage_100 = 0;
|
|
|
|
return false;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
success = bmp280_read(&data->temperature_celsius_100, &data->pressure_mbar_100, &data->humidity_percentage_100);
|
|
|
|
|
|
|
|
if (!success) {
|
|
|
|
log_info("BMP280 re-init\n");
|
|
|
|
success = bmp280_handler_init();
|
|
|
|
log_info("BMP280 re-init: %d\n", success);
|
|
|
|
|
|
|
|
if (success) {
|
|
|
|
success = bmp280_read(&data->temperature_celsius_100, &data->pressure_mbar_100, &data->humidity_percentage_100);
|
|
|
|
}
|
|
|
|
|
|
|
|
if (!success) {
|
|
|
|
data->temperature_celsius_100 = 0;
|
|
|
|
data->pressure_mbar_100 = 0;
|
|
|
|
data->humidity_percentage_100 = 0;
|
|
|
|
}
|
|
|
|
}
|
|
|
|
|
|
|
|
bmp280_initialization_required = !success;
|
|
|
|
|
|
|
|
return success;
|