RS-tracker/demod/iq_svcl
Zilog80 038674e6f1 IF-IQ server/client: test-min_fft_thd 2020-08-20 21:15:38 +02:00
..
README.md IF-IQ server/client: port number 2020-08-16 08:32:37 +02:00
iq_base.c baseband IQ: approx (prime) base_sr 900001 2020-08-20 14:38:58 +02:00
iq_base.h IF-IQ server/client: rename --scan -> --fft <file> 2020-08-08 16:06:56 +02:00
iq_client.c IF-IQ server/client: port number 2020-08-16 08:32:37 +02:00
iq_fm.c FM demod 2020-08-11 13:16:49 +02:00
iq_server.c IF-IQ server/client: test-min_fft_thd 2020-08-20 21:15:38 +02:00
iq_svcl.h IF-IQ server/client: port number 2020-08-16 08:32:37 +02:00
plot_fft.py display FFT data (2) 2020-08-15 20:05:50 +02:00
scan_fft.c IF-IQ server/client: scan FFT output 2020-08-16 00:33:35 +02:00

README.md

IQ server/client

receive IF stream from baseband IQ via TCP, default PORT=1280 (iq_svcl.h)

Compile

gcc -Ofast -c iq_base.c
gcc -O2 iq_server.c iq_base.o -lm -pthread -o iq_server
gcc -O2 iq_client.c -o iq_client

Usage/Examples

  • T1$ ./iq_server [--port <pn>] <iq_baseband.wav>
    T2$ ./iq_client [--ip <ip_adr>] [--port <pn>] --freq <fq>

  • Ex.1
    [terminal 1]
    T1$ ./iq_server --bo 32 <iq_baseband.wav>    (or   $ ./iq_server --bo 32 - <sr> <bs> <iq_baseband.raw>)
    [terminal 2]
    T2$ ./iq_client --freq <fq> | ./rs41mod -vx --IQ 0.0 --lp - <if_sr> <bo>
    where
         -0.5 < fq < 0.5: (relative) frequency, fq=frequency/sr
         <if_sr>: IF sample rate
         <bo>=8,16,32: output/IF bits per (real) sample (u8, s16 or f32)
    down-converts up to MAX_FQ=(4+1) (iq_base.h) channels/signals. More signals than number of CPUs/cores is not recommended.
    (Note: If the baseband sample rate has no appropriate factors (e.g. if prime), the IF sample rate might be high and IF-processing slow.)
    One channel can be used for scanning, --fft <fft.txt> makes FFT (2 seconds average). The FFT is saved in <fft.txt> as <fq>;<dB>, approx. 200 Hz per bin.
    If no output bps is chosen (--bo [8,16,32]), the IF bps is equal to the baseband bps. It is recommended to use --bo 32 (i.e. float32) output, then no quantization noise is introduced when converting from internal float32 samples.

  • Ex.2
    [terminal 1]
    T1$ rtl_sdr -f 403.0M -s 1920000 - | ./iq_server --fft fft_server.txt --bo 32 - 1920000 8
    [terminal 2]
    T2$ ./iq_client --freq -0.3125 | ./m10mod -c -vv --IQ 0.0 - 48000 32
    [terminal 3]
    T3$ ./iq_client --freq 0.0 | ./rs41mod -vx --IQ 0.0 - 48000 32
    [terminal 4]
    T4$ ./iq_client -1    (close channel 1)
    T4$ ./iq_client --stop    (close all clients and stop server)

The iq_server --fft option immediately starts reading the IQ stream (so buffering is reduced).
./iq_client --fft <fft_cl.txt> can also request FFT.
The IF sample rate if_sr is at least 48000 such that the baseband sample rate sr is a multiple of if_sr.