Packet Encoder: Fix num_bytes>=25 to num_bytes>25 so when a frame or remainder is exactly 25, it is still the final frame, and produces the EOT bit;
rodzic
65b1f62e51
commit
7280cf0f7e
|
@ -398,7 +398,10 @@ int main(int argc, char* argv[])
|
|||
//send packet frame syncword
|
||||
fill_syncword(full_packet, &pkt_sym_cnt, SYNC_PKT);
|
||||
|
||||
if(num_bytes>=25)
|
||||
//the following examples produce exactly 25 bytes, which exactly one frame, but >= meant this would never produce a final frame with EOT bit set
|
||||
//echo -en "\x05Testing M17 packet mo\x00" | ./m17-packet-encode -S N0CALL -D ALL -C 10 -n 23 -o float.sym -f
|
||||
//./m17-packet-encode -S N0CALL -D ALL -C 10 -o float.sym -f -T 'this is a simple text'
|
||||
if(num_bytes>25) //fix for frames that, with terminating byte and crc, land exactly on 25 bytes (or %25==0)
|
||||
{
|
||||
memcpy(pkt_chunk, &full_packet_data[pkt_cnt*25], 25);
|
||||
pkt_chunk[25]=pkt_cnt<<2;
|
||||
|
|
Ładowanie…