Andrew Rodland 8bf26f1fa0 Fix spurious writes when no RT-21 second port
The if condition for whether there actually is a second port is only
covering the sprintf for the elevation command, and not the write
attempt. So we call rotorez_send_priv_cmd2 whether rotport2 is valid or
not. When it's not, we try to write the command to fd 0 (stdin). When
running on the console, this results in trash on the console. When
runnning under something else (e.g. systemd) this results in errors or
other wierd behavior (e.g. EBADF because stdin isn't connected, causing
the command to fail with RIG_EIO).
2021-12-29 13:54:20 -05:00
..
Android.mk
Makefile.am
README.rotorez
rotorez.c Fix spurious writes when no RT-21 second port 2021-12-29 13:54:20 -05:00
rotorez.h
rotorez.txt

README.rotorez

Quirks, known bugs, and other notes.
====================================

In this document I'll try to describe the behavior of the Idiom Press
Rotor-EZ and RotorCard interfaces as well as the HyGain DCU-1/DCU-1X control
units with Hamlib.  For background information see rotorez/rotorez.txt.

The Idiom Press interfaces are the most capable of the units supported by
this backend and all available commands are supported by these units at this
time.  The HyGain control units only support a subset of the command set
involving rotor positioning.

This document is organized by Hamlib function calls and documents observed
behavior with each call.

rot_set_position
    *   Fractional values passed for azimuth are dropped. i.e. 180.6 becomes
        180 while a value greater than 359.4999 is converted to 0 for DCU1/
        DCU-1X compatibility.
    *   Allowed range for azimuth is 0 to 360.
    *   Values passed for elevation are ignored.  The protocol only supports
        azimuthal positioning

rot_get_position
    *   Position reading is returned in whole degrees from 0 to 359.
    *   Not supported by DCU-1/DCU-1X.

rotorez_rot_stop
    *   Causes immediate cessation of rotor positioning.
    *   Not supported by DCU-1/DCU-1X.

rot_set_conf
    *   Accepts one of E, e, J, j, O, o, S, and s (see rotorez/rotorez.txt)
        in *val.
    *   The value in token is not used by the backend and may be safely
        set to TOK_BACKEND_NONE.
    *   Not supported by DCU-1/DCU-1X.