Hamlib/doc/man1/rotctld.1

981 wiersze
21 KiB
Groff

.\" Hey, EMACS: -*- nroff -*-
.\"
.\" For layout and available macros, see man(7), man-pages(7), groff_man(7)
.\" Please adjust the date whenever revising the manpage.
.\"
.\" Note: Please keep this page in sync with the source, rotctld.c
.\"
.TH ROTCTLD "1" "2019-12-10" "Hamlib" "Hamlib Utilities"
.
.
.SH NAME
.
.
rotctld \- TCP rotator control daemon
.
.SH SYNOPSIS
.
.SY rotctld
.OP \-hlLuV
.OP \-m id
.OP \-r device
.OP \-s baud
.OP \-T IPADDR
.OP \-t number
.OP \-C parm=val
.RB [ \-v [ \-Z ]]
.YS
.
.
.SH DESCRIPTION
.
The
.B rotctld
program is a rotator control daemon that handles client requests via TCP
sockets. This allows multiple user programs to share one rotator (this needs
more development). Multiple rotators can be controlled on different TCP ports
by use of multiple
.B rotctld
processes. The syntax of the commands are the same as
.BR rotctl (1).
It is hoped that
.B rotctld
will be especially useful for client authors using languages such as Perl,
Python, PHP, and others.
.
.PP
.B rotctld
communicates to a client through a TCP socket using text commands shared with
.BR rotctl .
The protocol is simple, commands are sent to
.B rotctld
on one line and
.B rotctld
responds to \(lqget\(rq commands with the requested values, one per line, when
successful, otherwise, it responds with one line \(lqRPRT x\(rq, where
\(oqx\(cq is a negative number indicating the error code. Commands that do
not return values respond with the line \(lqRPRT x\(rq, where \(oqx\(cq is
\(oq0\(cq when successful, otherwise is a regative number indicating the error
code. Each line is terminated with a newline \(oq\\n\(cq character. This
protocol is primarily for use by the
.B NET rotctl
(rotator model 2) backend.
.
.PP
A separate
.B Extended Response Protocol
extends the above behavior by echoing the received command string as a header,
any returned values as a key: value pair, and the \(lqRPRT x\(rq string as the
end of response marker which includes the
.B Hamlib
success or failure value. See the
.B PROTOCOL
section for details. Consider using this protocol for clients that will
interact with
.B rotctld
directly through a TCP socket.
.
.PP
Keep in mind that Hamlib is BETA level software. While a lot of backend
libraries lack complete rotator support, the basic functions are usually well
supported.
.
.PP
Please report bugs and provide feedback at the e-mail address given in the
.B BUGS
section below. Patches and code enhancements sent to the same address are
welcome.
.
.
.SH OPTIONS
.
This program follows the usual GNU command line syntax. Short options that
take an argument may have the value follow immediately or be separated by a
space. Long options starting with two dashes (\(oq\-\(cq) require an
\(oq=\(cq between the option and any argument.
.
.PP
Here is a summary of the supported options:
.
.TP
.BR \-m ", " \-\-model = \fIid\fP
Select rotator model number.
.IP
See model list (use \(lqrotctld -l\(rq).
.IP
.BR Note :
.B rotctl
(or third party software using the C API) will use rotator model 2 for
.B NET rotctl
(this model number is not used for rotctld even though it shows in the model
list).
.
.TP
.BR \-r ", " \-\-rot\-file = \fIdevice\fP
Use
.I device
as the file name of the port connected to the rotator.
.IP
Often a serial port, but could be a USB to serial adapter. Typically
.IR /dev/ttyS0 ", " /dev/ttyS1 ", " /dev/ttyUSB0 ,
etc. on Linux,
.IR COM1 ", " COM2 ,
etc. on MS Windows. The BSD flavors and Mac OS/X have their own designations.
See your system's documentation.
.
.TP
.BR \-s ", " \-\-serial\-speed = \fIbaud\fP
Set serial speed to
.I baud
rate.
.IP
Uses maximum serial speed from rotator backend capabilities as the default.
.
.TP
.BR \-T ", " \-\-listen\-addr = \fIIPADDR\fP
Use
.I IPADDR
as the listening IP address.
.IP
The default is ANY.
.
.TP
.BR \-t ", " \-\-port = \fInumber\fP
Use
.I number
as the TCP listening port.
.IP
The default is 4533.
.IP
.BR Note :
As
.BR rigctld \(aqs
default port is 4532, it is advisable to use odd numbered ports for
.BR rotctld ,
e.g. 4533, 4535, 4537, etc.
.
.TP
.BR \-L ", " \-\-show\-conf
List all configuration parameters for the rotator defined with
.B \-m
above.
.
.TP
.BR \-C ", " \-\-set\-conf = \fIparm=val\fP [ \fI,parm=val\fP ]
Set rotator configuration parameter(s), e.g.
.IR stop_bits=2 .
.IP
Use the
.B -L
option above for a list of configuration parameters for a given model number.
.
.TP
.BR \-u ", " \-\-dump\-caps
Dump capabilities for the rotator defined with
.B -m
above and exit.
.
.TP
.BR \-l ", " \-\-list
List all rotator model numbers defined in
.B Hamlib
and exit.
.IP
The list is sorted by model number.
.IP
.BR Note :
In Linux the list can be scrolled back using
.BR Shift-PageUp / Shift-PageDown ,
or using the scrollbars of a virtual terminal in X or the cmd window in
Windows. The output can be piped to
.BR more (1)
or
.BR less (1),
e.g. \(lqrotctl -l | more\(rq.
.
.TP
.BR \-v ", " \-\-verbose
Set verbose mode, cumulative (see
.B DIAGNOSTICS
below).
.
.TP
.BR \-Z ", " \-\-debug\-time\-stamps
Enable time stamps for the debug messages.
.IP
Use only in combination with the
.B -v
option as it generates no output on its own.
.
.TP
.BR \-h ", " \-\-help
Show a summary of these options and exit.
.
.TP
.BR \-V ", " \-\-version
Show version of
.B rotctld
and exit.
.
.PP
.BR Note :
Some options may not be implemented by a given backend and will return an
error. This is most likely to occur with the
.B \-\-set\-conf
and
.B \-\-show\-conf
options.
.
.PP
Be aware that the backend for the rotator to be controlled, or the rotator
itself may not support some commands. In that case, the operation will fail
with a
.B Hamlib
error code.
.
.
.SH COMMANDS
.
Commands can be sent over the TCP socket either as a single char, or as a long
command name plus the value(s) space separated on one \(oq\\n\(cq terminated
line. See
.BR PROTOCOL .
.
.PP
Since most of the
.B Hamlib
operations have a
.BR set " and a " get
method, an upper case letter will be used for
.B set
methods whereas the corresponding lower case letter refers to the
.B get
method. Each operation also has a long name; prepend a backslash, \(oq\\\(cq,
to send a long command name.
.
.PP
Example (Perl): \(lqprint $socket "\\\\dump_caps\\n";\(rq to see what the
rotator's backend can do
.RB ( Note :
In Perl and many other languages a \(oq\\\(cq will need to be escaped with a
preceding \(oq\\\(cq so that even though two backslash characters appear in
the code, only one will be passed to
.BR rotctld .
This is a possible bug, beware!).
.
.PP
.BR Note :
The backend for the rotator to be controlled, or the rotator itself may not
support some commands. In that case, the operation will fail with a
.B Hamlib
error message.
.
.PP
Here is a summary of the supported commands (In the case of
.B set
commands the quoted italicized string is replaced by the value in the
description. In the case of
.B get
commands the quoted italicized string is the key name of the value returned.):
.
.TP
.BR P ", " set_pos " \(aq" \fIAzimuth\fP "\(aq \(aq" \fIElevation\fP \(aq
Set position.
.IP
.RI \(aq Azimuth \(aq
and
.RI \(aq Elevation \(aq
are floating point values.
.IP
For example:
.
.sp
.RS 1.0i
.EX
P 163.0 41.0
.EE
.RE
.IP
.BR Note :
If the rotator does not support setting elevation (most do not) supply
\(lq0.0\(rq for
.RI \(aq Elevation \(aq.
.
.TP
.BR p ", " get_pos
Get position.
.IP
.RI \(aq Azimuth \(aq
and
.RI \(aq Elevation \(aq
are returned as double precision floating point values.
.
.TP
.BR M ", " move " \(aq" \fIDirection\fP "\(aq \(aq" \fISpeed\fP \(aq
Move the rotator in a specific direction at the given rate.
.IP
.RI \(aq Direction \(aq
is an integer defined as \(oq2\(cq = Up, \(oq4\(cq = Down, \(oq8\(cq = Left,
and \(oq16\(cq = Right.
.IP
.RI \(aq Speed \(aq
is an integer between 1 and 100.
.IP
.BR Note :
Not all backends that implement the move command use the Speed value. At this
time only the gs232a utilizes the Speed parameter.
.
.TP
.BR S ", " stop
Stop the rotator.
.
.TP
.BR K ", " park
Park the rotator.
.
.TP
.BR C ", " set_conf " \(aq" \fIToken\fR "\(aq \(aq" \fIValue\fP \(aq
Set a configuration parameter.
.IP
.RI \(aq Token \(aq
is a string; see the
.B \-C
option and the
.B \-L
output.
.IP
.RI \(aq Value \(aq
is a string of up to 20 characters.
.\" FIXME: Need to describe the reset parameters available.
.
.TP
.BR R ", " reset " \(aq" \fIReset\fP \(aq
Reset the rotator.
.IP
.RI \(aq Reset \(aq
accepts an integer value of \(oq1\(cq for \(lqReset All\(rq.
.TP
.BR _ ", " get_info
Get misc information about the rotator.
.IP
Returns
.RI \(aq Info \(aq
\(lqModel Name\(rq.
.
.TP
.BR w ", " send_cmd " \(aq" \fICmd\fP \(aq
Send a raw command string to the rotator.
.IP
ASCII CR is appended automatically at the end of the command for text
protocols. For binary protocols, enter hexadecimal values as
\(lq\\0xAA\\0xBB\(rq.
.
.
.SS Locator Commands
.
These commands offer conversions of Degrees Minutes Seconds to other formats,
.B Maidenhead
square locator conversions and distance and azimuth conversions.
.TP
.BR L ", " lonlat2loc " \(aq" \fILongitude\fP "\(aq \(aq" \fILatitude\fP "\(aq \(aq" "\fILoc Len\fP" \(aq
Returns the
.B Maidenhead
.RI \(aq Locator \(aq
for the given
.RI \(aq Longitude "\(aq and \(aq" Latitude \(aq.
.IP
.RI \(aq Longitude "\(aq and \(aq" Latitude \(aq
are floating point values.
.IP
.RI \(aq "Loc Len" \(aq
is the precision of the returned square and should be an even numbered integer
value between 2 and 12.
.IP
For example:
.
.sp
.RS 1.0i
.EX
L -170.0 -85.0 12
.EE
.RE
.IP
returns:
.
.sp
.RS 1.0i
.EX
Locator: AA55AA00AA00
.EE
.RE
.
.TP
.BR l ", " loc2lonlat " \(aq" \fILocator\fP \(aq
Returns
.RI \(aq Longitude "\(aq and \(aq" Latitude \(aq
in decimal degrees at the approximate center of the requested
.B Maidenhead
grid square.
.IP
.RI \(aq Locator \(aq
can be from 2 to 12 characters in length.
.IP
West longitude is expressed as a negative value.
.IP
South latitude is
expressed as a negative value.
.IP
For example:
.
.sp
.RS 1.0i
.EX
l AA55AA00AA00
.EE
.RE
.IP
returns:
.
.sp
.RS 1.0i
.EX
Longitude: -169.999983 Latitude: -84.999991
.EE
.RE
.IP
.BR Note :
Despite the use of double precision variables internally, some rounding error
occurs.
.
.TP
.BR D ", " dms2dec " \(aq" \fIDegrees\fP "\(aq \(aq" \fIMinutes\fP "\(aq \(aq" \fISeconds\fP "\(aq \(aq" \fIS/W\fP \(aq
Returns
.RI \(aq "Dec Degrees" \(aq,
a signed floating point value.
.IP
.RI \(aq Degrees "\(aq and \(aq" Minutes \(aq
are integer values.
.IP
.RI \(aq Seconds \(aq
is a floating point value.
.IP
.RI \(aq S/W \(aq
is a flag with \(oq1\(cq indicating South latitude or West longitude and
\(oq0\(cq North or East (the flag is needed as computers don't recognize a
signed zero even though only the
.RI \(aq Degrees \(aq
value is typically signed in DMS notation).
.
.TP
.BR d ", " dec2dms " \(aq" "\fIDec Degrees\fP" \(aq
Returns
.RI \(aq Degrees "\(aq \(aq" Minutes "\(aq \(aq" Seconds "\(aq \(aq" S/W \(aq.
.IP
Values are as in
.B dms2dec
above.
.
.TP
.BR E ", " dmmm2dec " \(aq" \fIDegrees\fP "\(aq \(aq" "\fIDec Minutes\fP" "\(aq \(aq" \fIS/W\fP \(aq
Returns
.RI \(aq "Dec Degrees" \(aq,
a signed floating point value.
.IP
.RI \(aq Degrees \(aq
is an integer value.
.IP
.RI \(aq "Dec Minutes" \(aq
is a floating point value.
.IP
.RI \(aq S/W \(aq
is a flag as in
.B dms2dec
above.
.
.TP
.BR e ", " dec2dmmm " \(aq" "\fIDec Deg\fP" \(aq
Returns
.RI \(aq Degrees "\(aq \(aq" Minutes "\(aq \(aq" S/W \(aq.
.IP
Values are as in
.B dmmm2dec
above.
.
.TP
.BR B ", " qrb " \(aq" "\fILon 1\fP" "\(aq \(aq" "\fILat 1\fP" "\(aq \(aq" "\fILon 2\fP" "\(aq \(aq" "\fILat 2\fP" \(aq
Returns
.RI \(aq Distance "\(aq and \(aq" Azimuth \(aq.
.IP
.RI \(aq Distance \(aq
is in km.
.IP
.RI \(aq Azimuth \(aq
is in degrees.
.IP
Supplied
.IR Lon / Lat
values are signed floating point numbers.
.
.TP
.BR A ", " a_sp2a_lp " \(aq" "\fIShort Path Deg\fP" \(aq
Returns
.RI \(aq "Long Path Deg" \(aq.
.IP
Both the supplied argument and returned value are floating point values within
the range of 0.00 to 360.00.
.IP
.BR Note :
Supplying a negative value will return an error message.
.
.TP
.BR a ", " d_sp2d_lp " \(aq" "\fIShort Path km\fP" \(aq
Returns
.RI \(aq "Long Path km" \(aq.
.IP
Both the supplied argument and returned value are floating point values.
.
.TP
.BR pause " \(aq" \fISeconds\fP \(aq
Pause for the given whole (integer) number of
.RI \(aq Seconds \(aq
before sending the next command to the rotator.
.
.
.SH PROTOCOL
.
There are two protocols in use by
.BR rotctld ,
the
.B Default Protocol
and the
.BR "Extended Response Protocol" .
.
.PP
The
.B Default Protocol
is intended primarily for the communication between
.B Hamlib
library functions and
.B rotctld
(\(lqNET rotctl\(rq, available using rotator model \(oq2\(cq).
.
.PP
The
.B Extended Response Protocol
is intended to be used with scripts or other programs interacting directly
with
.B rotctld
as consistent feedback is provided.
.
.
.SS Default Protocol
.
The
.B Default Protocol
is intentionally simple. Commands are entered on a single line with any
needed values. In practice, reliable results are obtained by terminating each
command string with a newline character, \(oq\\n\(cq.
.
.PP
Example set position (Perl code):
.
.sp
.RS 0.5i
.EX
print $socket "P 135 10\\n";
.EE
.RE
.
.PP
or:
.
.sp
.RS 0.5i
.EE
print $socket "\\\\set_pos 135 10\\n"; # escape leading \(oq\\\(cq
.EE
.RE
.
.PP
A one line response will be sent as a reply to
.B set
commands, \(lqRPRT \fIx\fP\\n\(rq where
.I x
is the Hamlib error code with \(oq0\(cq indicating success of the command.
.
.PP
Responses from
.B rotctld
.B get
commands are text values and match the same tokens used in the
.B set
commands. Each value is returned on its own line. On error the string \(lqRPRT
\fIx\fP\\n\(rq is returned where
.I x
is the Hamlib error code.
.
.PP
Example get position (Perl code):
.
.sp
.RS 0.5i
.EX
print $socket "p\\n";
.br
"135"
.br
"10"
.EE
.RE
.
.PP
Most
.B get
functions return one to three values. A notable exception is the
.B dump_caps
command which returns many lines of
\fBkey\fR:\fIvalue\fR
pairs.
.
.PP
This protocol is primarily used by the \(lqNET rotctl\(rq (rotctl model 2)
backend which allows applications already written for Hamlib's C API to take
advantage of
.B rotctld
without the need of rewriting application code. An application's user can
select rotator model 2 (\(lqNET rotctl\(rq) and then set
.B rot_pathname
to \(lqlocalhost:4533\(rq or other network
.IR host : port
(set by the
.BR \-T / \-t
options, respectively, above).
.
.
.SS Extended Response Protocol
.
The Extended Response protocol adds several rules to the strings returned by
.B rotctld
and adds a rule for the command syntax.
.
.PP
1. The command received by
.B rotctld
is echoed with its long command name followed by the value(s) (if any)
received from the client terminated by the specified response separator as the
first record of the response.
.
.PP
2. The last record of each block is the string \(lqRPRT \fIx\fP\\n\(rq where
.I x
is the numeric return value of the Hamlib backend function that was called by
the command.
.
.PP
3. Any records consisting of data values returned by the rotator backend are
prepended by a string immediately followed by a colon then a space and then
the value terminated by the response separator, e.g. \(lqAzimuth:
90.000000\\n\(rq when the command was prepended by \(oq+\(cq.
.
.PP
4. All commands received will be acknowledged by
.B rotctld
with records from rules 1 and 2. Records from rule 3 are only returned when
data values must be returned to the client.
.
.PP
An example response to a
.B P
command sent from the shell prompt (note the prepended \(oq+\(cq):
.
.sp
.RS 0.5i
.EX
$ echo "+P 90 45" | nc -w 1 localhost 4533
.br
set_pos: 90 45
.br
RPRT 0
.EE
.RE
.
.PP
In this case the long command name and values are returned on the first line
and the second line contains the end of block marker and the numeric rotor
backend return value indicating success.
.
.PP
An example response to a
.B get_pos
query:
.
.sp
.RS 0.5i
.EX
$ echo "+\\get_pos" | nc -w 1 localhost 4533
.br
get_pos:
.br
Azimuth: 90.000000
.br
Elevation: 45.000000
.br
RPRT 0
.EE
.RE
.IP
.BR Note :
The \(oq\\\(cq is still required for the long command name even with the ERP
character.
.
.PP
In this case, as no value is passed to
.BR rotctld ,
the first line consists only of the long command name. The final line shows
that the command was processed successfully by the rotor backend.
.
.PP
Invoking the Extended Response Protocol requires prepending a command with a
punctuation character. As shown in the examples above, prepending a \(oq+\(cq
character to the command results in the responses being separated by a newline
character (\(oq\\n\(cq). Any other punctuation character recognized by the C
.BR ispunct ()
function except \(oq\\\(cq, \(oq?\(cq, or \(oq_\(cq will cause that character
to become the response separator and the entire response will be on one line.
.
.PP
Separator character summary:
.
.TP
.RB \(oq + \(cq
Each record of the response is appended with a newline (\(oq\\n\(cq).
.
.TP
.RB \(oq ; "\(cq, \(oq" | "\(cq, or, \(oq" , \(cq
Each record of the response is appended by the given character resulting in
entire response on one line.
.IP
These are common record separators for text representations of spreadsheet
data, etc.
.
.TP
.RB \(oq ? \(cq
Reserved for help in
.BR rotctl .
.
.TP
.RB \(oq _ \(cq
Reserved for
.B get_info
short command
.
.TP
.RB \(oq # \(cq
Reserved for comments when reading a command file script.
.IP
.BR Note :
Other punctuation characters have not been tested! Use at your own risk.
.
.PP
For example, invoking a
.B get_pos
query with a leading \(oq;\(cq returns:
.
.sp
.RS 0.5i
.EX
get_pos:;Azimuth: 90.000000;Elevation: 45.000000;RPRT 0
.EE
.RE
.
.PP
Or, using the pipe character \(oq|\(cq returns:
.
.sp
.RS 0.5i
.EX
get_pos:|Azimuth: 90.000000|Elevation: 45.000000|RPRT 0
.EE
.RE
.
.PP
And a
.B set_pos
command prepended with a \(oq|\(cq returns:
.
.sp
.RS 0.5i
.EX
set_pos: 135 22.5|RPRT 0
.EE
.RE
.
.PP
Such a format will allow reading a response as a single event using a preferred
response separator. Other punctuation characters have not been tested!
.
.PP
All commands with the exception of
.B set_conf
have been tested with the Extended Response protocol and the included
.B testrotctld.pl
Perl script.
.
.
.SH DIAGNOSTICS
.
The
.BR \-v ,
.B \-\-verbose
option allows different levels of diagnostics
to be output to
.B stderr
and correspond to \-v for
.BR BUG ,
\-vv for
.BR ERR ,
\-vvv for
.BR WARN ,
\-vvvv for
.BR VERBOSE ,
or \-vvvvv for
.BR TRACE .
.
.PP
A given verbose level is useful for providing needed debugging information to
the email address below. For example, TRACE output shows all of the values
sent to and received from the radio which is very useful for radio backend
library development and may be requested by the developers.
.
.
.SH EXAMPLE
.
Start
.B rotctld
for a Hy-Gain Ham IV rotor with the Idiom Press RotorEZ board installed using
a USB-to-serial adapter and backgrounding:
.
.sp
.RS 0.5i
.EX
$ rotctld \-m 401 \-r /dev/ttyUSB1 &
.EE
.RE
.
.PP
Start
.B rotctld
for RotorEZ using COM2 on Win32:
.
.sp
.RS 0.5i
.EX
.RE
$ rotctl \-m 401 \-r COM2
.EE
.
.PP
Connect to the already running
.BR rotctld ,
and set position to 135.0 degrees azimuth and 30.0 degrees elevation with a 1
second read timeout from the shell prompt:
.
.sp
.RS 0.5i
.EX
$ echo "\\set_pos 135.0 30.0" | nc \-w 1 localhost 4533
.EE
.RE
.
.PP
Connect to a running
.B rotctld
with
.B rotctl
on the local host:
.sp
.RS 0.5i
.EX
$ rotctl \-m 2
.EE
.RE
.
.
.SH SECURITY
.
No authentication whatsoever; DO NOT leave this TCP port open wide to the
Internet. Please ask if stronger security is needed or consider using a
Secure Shell
.RB ( ssh (1))
tunnel.
.
.PP
As
.B rotctld
does not need any greater permissions than
.BR rotctl ,
it is advisable to not start
.B rotctld
as \(lqroot\(rq or another system user account in order to limit any
vulnerability.
.
.
.SH BUGS
.
The daemon is not detaching and backgrounding itself.
.
.PP
No method to exit the daemon so the
.BR kill (1)
command must be used to terminate it.
.
.PP
Multiple clients using the daemon may experience contention with the connected
rotator.
.
.PP
Report bugs to:
.IP
.nf
.MT hamlib\-developer@lists.sourceforge.net
Hamlib Developer mailing list
.ME
.fi
.
.
.SH COPYING
.
This file is part of Hamlib, a project to develop a library that simplifies
radio, rotator, and amplifier control functions for developers of software
primarily of interest to radio amateurs and those interested in radio
communications.
.
.PP
Copyright \(co 2000-2009 Stephane Fillod
.br
Copyright \(co 2000-2018 the Hamlib Group (various contributors)
.br
Copyright \(co 2011-2019 Nate Bargmann
.
.PP
This is free software; see the file COPYING for copying conditions. There is
NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
.
.
.SH SEE ALSO
.
.BR kill (1),
.BR rotctl (1),
.BR ssh (1),
.BR hamlib (7)
.
.
.SH COLOPHON
.
Links to the Hamlib Wiki, Git repository, release archives, and daily snapshot
archives:
.IP
.UR http://www.hamlib.org
hamlib.org
.UE .