.\" Hey, EMACS: -*- nroff -*-
|
|
.\"
|
|
.\" For layout and available macros, see man(7), man-pages(7), groff_man(7)
|
|
.\" Please adjust the date whenever revising the manpage.
|
|
.\"
|
|
.\" Note: Please keep this page in sync with the source, ampctld.c
|
|
.\"
|
|
.TH AMPCTLD "1" "2019-12-10" "Hamlib" "Hamlib Utilities"
|
|
.
|
|
.
|
|
.SH NAME
|
|
.
|
|
ampctld \- TCP amplifier control daemon
|
|
.
|
|
.
|
|
.SH SYNOPSIS
|
|
.
|
|
.SY ampctld
|
|
.OP \-hlLuV
|
|
.OP \-m id
|
|
.OP \-r device
|
|
.OP \-s baud
|
|
.OP \-T IPADDR
|
|
.OP \-t number
|
|
.OP \-C parm=val
|
|
.RB [ \-v [ \-Z ]]
|
|
.YS
|
|
.
|
|
.
|
|
.SH DESCRIPTION
|
|
.
|
|
The
|
|
.B ampctld
|
|
program is an amplifier control daemon that handles client requests via TCP
|
|
sockets. This allows multiple user programs to share one amplifier (this
|
|
needs more development). Multiple amplifiers can be controlled on different
|
|
TCP ports by use of multiple
|
|
.B ampctld
|
|
processes. Note that multiple processes/ports are also necessary if some
|
|
clients use extended responses and/or vfo mode. So up to 4 processes/ports
|
|
may be needed for each combination of extended response/vfo mode. The syntax
|
|
of the commands are the same as
|
|
.BR ampctl (1).
|
|
It is hoped that
|
|
.B ampctld
|
|
will be especially useful for client authors using languages such as Perl,
|
|
Python, PHP, and others.
|
|
.
|
|
.PP
|
|
.B ampctld
|
|
communicates to a client through a TCP socket using text commands shared with
|
|
.BR ampctl .
|
|
The protocol is simple, commands are sent to
|
|
.B ampctld
|
|
on one line and
|
|
.B ampctld
|
|
responds to
|
|
.B get
|
|
commands with the requested values, one per line, when successful, otherwise,
|
|
it responds with one line \(lqRPRT x\(rq, where \(oqx\(cq is a negative number
|
|
indicating the error code. Commands that do not return values respond with
|
|
the line \(lqRPRT x\(rq, where \(oqx\(cq is \(oq0\(cq when successful,
|
|
otherwise is a regative number indicating the error code. Each line is
|
|
terminated with a newline \(oq\\n\(cq character. This protocol is primarily
|
|
for use by the
|
|
.B NET ampctl
|
|
(amplifier model 2) backend.
|
|
.
|
|
.PP
|
|
A separate
|
|
.B Extended Response Protocol
|
|
extends the above behavior by echoing the received command string as a header,
|
|
any returned values as a key: value pair, and the \(lqRPRT x\(rq string as the
|
|
end of response marker which includes the
|
|
.B Hamlib
|
|
success or failure value. See the
|
|
.B PROTOCOL
|
|
section for details. Consider using this protocol for clients that will
|
|
interact with
|
|
.B ampctld
|
|
directly through a TCP socket.
|
|
.
|
|
.PP
|
|
Keep in mind that Hamlib is BETA level software. While a lot of backend
|
|
libraries lack complete amplifier support, the basic functions are usually
|
|
well supported.
|
|
.
|
|
.PP
|
|
Please report bugs and provide feedback at the e-mail address given in the
|
|
.B BUGS
|
|
section below. Patches and code enhancements sent to the same address are
|
|
welcome.
|
|
.
|
|
.
|
|
.SH OPTIONS
|
|
.
|
|
This program follows the usual GNU command line syntax. Short options that
|
|
take an argument may have the value follow immediately or be separated by a
|
|
space. Long options starting with two dashes (\(oq\-\(cq) require an
|
|
\(oq=\(cq between the option and any argument.
|
|
.
|
|
.PP
|
|
Here is a summary of the supported options:
|
|
.
|
|
.TP
|
|
.BR \-m ", " \-\-model = \fIid\fP
|
|
Select amplifier model number.
|
|
.IP
|
|
See model list (use \(lqampctl -l\(rq).
|
|
.IP
|
|
.BR Note :
|
|
.B ampctl
|
|
(or third party software using the C API) will use amplifier model 2 for
|
|
.B NET ampctl
|
|
(communicating with
|
|
.BR ampctld ).
|
|
.
|
|
.TP
|
|
.BR \-r ", " \-\-amp\-file = \fIdevice\fP
|
|
Use
|
|
.I device
|
|
as the file name of the port connected to the amplifier.
|
|
.IP
|
|
Often a serial port, but could be a USB to serial adapter. Typically
|
|
.IR /dev/ttyS0 ", " /dev/ttyS1 ", " /dev/ttyUSB0 ,
|
|
etc. on Linux,
|
|
.IR COM1 ", " COM2 ,
|
|
etc. on MS Windows. The BSD flavors and Mac OS/X have their own designations.
|
|
See your system's documentation.
|
|
.
|
|
.TP
|
|
.BR \-s ", " \-\-serial\-speed = \fIbaud\fP
|
|
Set serial speed to
|
|
.I baud
|
|
rate.
|
|
.IP
|
|
Uses maximum serial speed from amplifier backend capabilities (set by
|
|
.B -m
|
|
above) as the default.
|
|
.
|
|
.TP
|
|
.BR \-t ", " \-\-port = \fInumber\fP
|
|
Use
|
|
.I number
|
|
as the TCP listening port.
|
|
.IP
|
|
The default is 4531.
|
|
.IP
|
|
.BR Note :
|
|
As
|
|
.BR rigctld 's
|
|
default port is 4532 and
|
|
.BR rotctld 's
|
|
default port is 4533, it is recommended to use DESCENDING odd numbered ports
|
|
for multiple
|
|
.BR ampctld
|
|
instances, e.g. 4529, 4527, 4525, etc.
|
|
.
|
|
.TP
|
|
.BR \-T ", " \-\-listen\-addr = \fIIPADDR\fP
|
|
Use
|
|
.I IPADDR
|
|
as the listening IP address.
|
|
.IP
|
|
The default is ANY.
|
|
.
|
|
.TP
|
|
.BR \-L ", " \-\-show\-conf
|
|
List all config parameters for the amplifier defined with
|
|
.B \-m
|
|
above.
|
|
.
|
|
.TP
|
|
.BR \-C ", " \-\-set\-conf = \fIparm=val\fP [ \fI,parm=val\fP ]
|
|
Set amplifier configuration parameter(s), e.g.
|
|
.IR stop_bits=2 .
|
|
.IP
|
|
Use the
|
|
.B -L
|
|
option above for a list of configuration parameters for a given model number.
|
|
.
|
|
.TP
|
|
.BR \-u ", " \-\-dump\-caps
|
|
Dump capabilities for the amplifier defined with
|
|
.B -m
|
|
above and exit.
|
|
.
|
|
.TP
|
|
.BR \-l ", " \-\-list
|
|
List all amplifier model numbers defined in
|
|
.B Hamlib
|
|
and exit.
|
|
.IP
|
|
The list is sorted by model number.
|
|
.IP
|
|
.BR Note :
|
|
In Linux the list can be scrolled back using
|
|
.BR Shift-PageUp / Shift-PageDown ,
|
|
or using the scrollbars of a virtual terminal in X or the cmd window in
|
|
Windows. The output can be piped to
|
|
.BR more (1)
|
|
or
|
|
.BR less (1),
|
|
e.g. \(lqampctl -l | more\(rq.
|
|
.
|
|
.TP
|
|
.BR \-v ", " \-\-verbose
|
|
Set verbose mode, cumulative (see
|
|
.B DIAGNOSTICS
|
|
below).
|
|
.
|
|
.TP
|
|
.BR \-Z ", " \-\-debug\-time\-stamps
|
|
Enable time stamps for the debug messages.
|
|
.IP
|
|
Use only in combination with the
|
|
.B -v
|
|
option as it generates no output on its own.
|
|
.
|
|
.TP
|
|
.BR \-h ", " \-\-help
|
|
Show a summary of these options and exit.
|
|
.
|
|
.TP
|
|
.BR \-V ", " \-\-version
|
|
Show version of
|
|
.B ampctl
|
|
and exit.
|
|
.
|
|
.PP
|
|
.BR Note :
|
|
Some options may not be implemented by a given backend and will return an
|
|
error. This is most likely to occur with the
|
|
.B \-\-set\-conf
|
|
and
|
|
.B \-\-show\-conf
|
|
options.
|
|
.
|
|
.PP
|
|
Please note that the backend for the amplifier to be controlled, or the
|
|
amplifier itself may not support some commands. In that case, the operation
|
|
will fail with a
|
|
.B Hamlib
|
|
error code.
|
|
.
|
|
.
|
|
.SH COMMANDS
|
|
.
|
|
Commands can be sent over the TCP socket either as a single char, or as a long
|
|
command name plus the value(s) space separated on one \(oq\\n\(cq terminated
|
|
line. See
|
|
.BR PROTOCOL .
|
|
.
|
|
.PP
|
|
Since most of the
|
|
.B Hamlib
|
|
operations have a
|
|
.B set
|
|
and a
|
|
.B get
|
|
method, an upper case letter will be used for
|
|
.B set
|
|
methods whereas the corresponding lower case letter refers to the
|
|
.B get
|
|
method. Each operation also has a long name; prepend a backslash, \(oq\\\(cq,
|
|
to send a long command name.
|
|
.
|
|
.PP
|
|
Example (Perl): \(lqprint $socket "\\\\dump_caps\\n";\(rq to see what the
|
|
amplifier's backend can do
|
|
.RB ( Note :
|
|
In Perl and many other languages a \(oq\\\(cq will need to be escaped with a
|
|
preceding \(oq\\\(cq so that even though two backslash characters appear in
|
|
the code, only one will be passed to
|
|
.BR ampctld .
|
|
This is a possible bug, beware!).
|
|
.
|
|
.PP
|
|
.BR Note :
|
|
The backend for the amplifier to be controlled, or the amplifier itself may
|
|
not support some commands. In that case, the operation will fail with a
|
|
.B Hamlib
|
|
error message.
|
|
.
|
|
.PP
|
|
Here is a summary of the supported commands (In the case of
|
|
.B set
|
|
commands the quoted italicized string is replaced by the value in the
|
|
description. In the case of
|
|
.B get
|
|
commands the quoted italicized string is the key name of the value returned.):
|
|
.
|
|
.TP
|
|
.BR F ", " set_freq " \(aq" \fIFrequency\fP \(aq
|
|
Set
|
|
.RI \(aq Frequency \(aq,
|
|
in Hz.
|
|
.IP
|
|
Frequency may be a floating point or integer value.
|
|
.
|
|
.TP
|
|
.BR f ", " get_freq
|
|
Get
|
|
.RI \(aq Frequency \(aq,
|
|
in Hz.
|
|
.IP
|
|
Returns an integer value.
|
|
.
|
|
.TP
|
|
.BR l ", " get_level " \(aq" \fILevel\fP \(aq
|
|
Get
|
|
.RI \(aq "Level Value" \(aq.
|
|
.IP
|
|
Returns Level Value as a float or integer for the Level token given.
|
|
.IP
|
|
.BR Note :
|
|
Passing a \(oq?\(cq (query) as the first argument instead of a Level token
|
|
will return a space separated list of amplifier backend supported get level
|
|
tokens. Use this to determine the supported levels of a given amplifier
|
|
backend.
|
|
.
|
|
.TP
|
|
.B dump_state
|
|
Return certain state information about the amplifier backend.
|
|
.
|
|
.TP
|
|
.BR 1 ", " dump_caps
|
|
Not a real amplifier remote command, it just dumps capabilities, i.e. what the
|
|
backend knows about this model, and what it can do.
|
|
.IP
|
|
TODO: Ensure this is in a consistent format so it can be read into a hash,
|
|
dictionary, etc. Bug reports requested.
|
|
.IP
|
|
.BR Note :
|
|
This command will produce many lines of output so be very careful if using a
|
|
fixed length array! For example, running this command against the Dummy
|
|
backend results in a number of lines of text output.
|
|
.
|
|
.TP
|
|
.BR _ ", " get_info
|
|
Return information from the amplifier backend.
|
|
.
|
|
.TP
|
|
.BR R ", " reset " \(aq" \fIReset\fP \(aq
|
|
Perform amplifier
|
|
.RI \(aq Reset \(aq.
|
|
.IP
|
|
Reset is an integer value: \(oq0\(cq = None, \(oq1\(cq = Memory reset,
|
|
\(oq2\(cq = Fault reset, \(oq3\(cq = Amplifier reset.
|
|
.
|
|
.TP
|
|
.BR set_powerstat " \(aq" "\fIPower Status\fP" \(aq
|
|
Set
|
|
.RI \(aq "Power Status" \(aq.
|
|
.IP
|
|
Power Status is an integer value: \(oq0\(cq = Power Off, \(oq1\(cq = Power On,
|
|
\(oq2\(cq = Power Standby (enter standby), \(oq4\(cq = Power Operate (leave
|
|
standby).
|
|
.
|
|
.TP
|
|
.B get_powerstat
|
|
Get
|
|
.RI \(aq "Power Status" \(aq
|
|
as in
|
|
.B set_powerstat
|
|
above.
|
|
.
|
|
.
|
|
.SH PROTOCOL
|
|
.
|
|
There are two protocols in use by
|
|
.BR ampctld ,
|
|
the
|
|
.B Default Protocol
|
|
and the
|
|
.BR "Extended Response Protocol" .
|
|
.
|
|
.PP
|
|
The
|
|
.B Default Protocol
|
|
is intended primarily for the communication between
|
|
.B Hamlib
|
|
library functions and
|
|
.B ampctld
|
|
(\(lqNET ampctl\(rq, available using amplifier model \(oq2\(cq).
|
|
.
|
|
.PP
|
|
The
|
|
.B Extended Response Protocol
|
|
is intended to be used with scripts or other programs interacting directly
|
|
with
|
|
.B ampctld
|
|
as consistent feedback is provided.
|
|
.
|
|
.
|
|
.SS Default Protocol
|
|
.
|
|
The
|
|
.B Default Protocol
|
|
is intentionally simple. Commands are entered on a single line with any
|
|
needed values. In practice, reliable results are obtained by terminating each
|
|
command string with a newline character, \(oq\\n\(cq.
|
|
.
|
|
.PP
|
|
Example set frequency and mode commands (Perl code):
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
print $socket "F 14250000\\n";
|
|
.br
|
|
print $socket "\\\\set_powerstat 1\\n"; # escape leading '\\'
|
|
.EE
|
|
.RE
|
|
.
|
|
.PP
|
|
A one line response will be sent as a reply to
|
|
.B set
|
|
commands, \(lqRPRT \fIx\fP\\n\(rq where
|
|
.I x
|
|
is the Hamlib error code with \(oq0\(cq indicating success of the command.
|
|
.
|
|
.PP
|
|
Responses from
|
|
.B ampctld
|
|
.B get
|
|
commands are text values and match the same tokens used in the
|
|
.B set
|
|
commands. Each value is returned on its own line. On error the string \(lqRPRT
|
|
\fIx\fP\\n\(rq is returned where
|
|
.I x
|
|
is the Hamlib error code.
|
|
.
|
|
.PP
|
|
Example get frequency (Perl code):
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
print $socket "f\\n";
|
|
.br
|
|
"14250000\\n"
|
|
.EE
|
|
.RE
|
|
.
|
|
.PP
|
|
Most
|
|
.B get
|
|
functions return one to three values. A notable exception is the
|
|
.B dump_caps
|
|
command which returns many lines of
|
|
\fBkey\fR:\fIvalue\fR
|
|
pairs.
|
|
.
|
|
.PP
|
|
This protocol is primarily used by the \(lqNET ampctl\(rq (ampctl model 2)
|
|
backend which allows applications already written for Hamlib's C API to take
|
|
advantage of
|
|
.B ampctld
|
|
without the need of rewriting application code. An application's user can
|
|
select amplifier model 2 (\(lqNET ampctl\(rq) and then set
|
|
.B amp_pathname
|
|
to \(lqlocalhost:4531\(rq or other network
|
|
.IR host : port
|
|
(set by the
|
|
.BR \-T / \-t
|
|
options, respectively, above).
|
|
.
|
|
.
|
|
.SS Extended Response Protocol
|
|
.
|
|
The Extended Response protocol adds several rules to the strings returned by
|
|
.B ampctld
|
|
and adds a rule for the command syntax.
|
|
.
|
|
.PP
|
|
1. The command received by
|
|
.B ampctld
|
|
is echoed with its long command name followed by the value(s) (if any)
|
|
received from the client terminated by the specified response separator as the
|
|
first record of the response.
|
|
.
|
|
.PP
|
|
2. The last record of each block is the string \(lqRPRT \fIx\fP\\n\(rq where
|
|
.I x
|
|
is the numeric return value of the Hamlib backend function that was called by
|
|
the command.
|
|
.
|
|
.PP
|
|
3. Any records consisting of data values returned by the amplifier backend are
|
|
prepended by a string immediately followed by a colon then a space and then
|
|
the value terminated by the response separator. e.g. \(lqFrequency:
|
|
14250000\\n\(rq when the command was prepended by \(oq+\(cq.
|
|
.
|
|
.PP
|
|
4. All commands received will be acknowledged by
|
|
.B ampctld
|
|
with records from rules 1 and 2. Records from rule 3 are only returned when
|
|
data values must be returned to the client.
|
|
.
|
|
.PP
|
|
4. All commands received will be acknowledged by
|
|
.B ampctld
|
|
with records from rules 1 and 2. Records from rule 3 are only returned when
|
|
data values must be returned to the client.
|
|
.
|
|
.PP
|
|
An example response to a
|
|
.B set_frequency
|
|
command sent from the shell prompt (note the prepended \(oq+\(cq):
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
$ echo "+F 14250000" | nc -w 1 localhost 4531
|
|
.br
|
|
set_freq: 14250000
|
|
.br
|
|
RPRT 0
|
|
.EE
|
|
.RE
|
|
.
|
|
.PP
|
|
In this case the long command name and values are returned on the first line
|
|
and the second line contains the end of block marker and the numeric amplifier
|
|
backend return value indicating success.
|
|
.
|
|
.PP
|
|
An example response to a
|
|
.B get_freq
|
|
query:
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
$ echo "+\\get_freq" | nc -w 1 localhost 4531
|
|
.br
|
|
get_freq:
|
|
.br
|
|
Frequency(Hz): 14250000
|
|
.br
|
|
RPRT 0
|
|
.EE
|
|
.RE
|
|
.
|
|
.IP
|
|
.BR Note :
|
|
The \(oq\\\(cq is still required for the long command name even with the ERP
|
|
character.
|
|
.
|
|
.PP
|
|
In this case, as no value is passed to
|
|
.BR ampctld ,
|
|
the first line consists only of the long command name. The final line shows
|
|
that the command was processed successfully by the amplifier backend.
|
|
.
|
|
.PP
|
|
Invoking the Extended Response Protocol requires prepending a command with a
|
|
punctuation character. As shown in the examples above, prepending a \(oq+\(cq
|
|
character to the command results in the responses being separated by a newline
|
|
character (\(oq\\n\(cq). Any other punctuation character recognized by the C
|
|
.BR ispunct ()
|
|
function except \(oq\\\(cq, \(oq?\(cq, or \(oq_\(cq will cause that character
|
|
to become the response separator and the entire response will be on one line.
|
|
.
|
|
.PP
|
|
Separator character summary:
|
|
.TP
|
|
.RB \(oq + \(cq
|
|
Each record of the response is appended with a newline (\(oq\\n\(cq).
|
|
.
|
|
.TP
|
|
.RB \(oq ; "\(cq, \(oq" | "\(cq, or, \(oq" , \(cq
|
|
Each record of the response is appended by the given character resulting in
|
|
entire response on one line.
|
|
.IP
|
|
These are common record separators for text representations of spreadsheet
|
|
data, etc.
|
|
.
|
|
.TP
|
|
.RB \(oq ? \(cq
|
|
Reserved for help in
|
|
.BR ampctl .
|
|
.
|
|
.TP
|
|
.RB \(oq _ \(cq
|
|
Reserved for
|
|
.B get_info
|
|
short command
|
|
.
|
|
.TP
|
|
.RB \(oq # \(cq
|
|
Reserved for comments when reading a command file script.
|
|
.IP
|
|
.BR Note :
|
|
Other punctuation characters have not been tested! Use at your own risk.
|
|
.
|
|
.PP
|
|
For example, invoking a
|
|
.B get_freq
|
|
query with a leading \(oq;\(cq returns:
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
get_freq:;Frequency(Hz): 14250000;RPRT 0
|
|
.EE
|
|
.RE
|
|
.
|
|
.PP
|
|
Or, using the pipe character \(oq|\(cq returns:
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
get_freq:|Frequency(Hz): 14250000|RPRT 0
|
|
.EE
|
|
.RE
|
|
.
|
|
.PP
|
|
And a
|
|
.B set_freq
|
|
command prepended with a \(oq|\(cq returns:
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
set_freq: 14250000|RPRT 0
|
|
.EE
|
|
.RE
|
|
.
|
|
.PP
|
|
Such a format will allow reading a response as a single event using a preferred
|
|
response separator. Other punctuation characters have not been tested!
|
|
.
|
|
.SH DIAGNOSTICS
|
|
.
|
|
The
|
|
.BR \-v ,
|
|
.B \-\-verbose
|
|
option allows different levels of diagnostics
|
|
to be output to
|
|
.B stderr
|
|
and correspond to \-v for
|
|
.BR BUG ,
|
|
\-vv for
|
|
.BR ERR ,
|
|
\-vvv for
|
|
.BR WARN ,
|
|
\-vvvv for
|
|
.BR VERBOSE ,
|
|
or \-vvvvv for
|
|
.BR TRACE .
|
|
.
|
|
.PP
|
|
A given verbose level is useful for providing needed debugging information to
|
|
the email address below. For example, TRACE output shows all of the values
|
|
sent to and received from the amplifier which is very useful for amplifier
|
|
backend library development and may be requested by the developers.
|
|
.
|
|
.
|
|
.SH EXAMPLE
|
|
.
|
|
Start
|
|
.B ampctld
|
|
for an Elecraft KPA-1500 using a USB-to-serial adapter and backgrounding:
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
$ ampctld -m 201 -r /dev/ttyUSB1 &
|
|
.EE
|
|
.RE
|
|
.
|
|
.PP
|
|
Start
|
|
.B ampctld
|
|
for an Elecraft KPA-1500 using COM2 on MS Windows:
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
$ ampctld -m 201 -r COM2
|
|
.EE
|
|
.RE
|
|
.
|
|
.PP
|
|
Connect to the already running
|
|
.B ampctld
|
|
and set the frequency to 14.266 MHz with a 1 second read timeout using the
|
|
default protocol from the shell prompt:
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
$ echo "\\set_freq 14266000" | nc -w 1 localhost 4531
|
|
.EE
|
|
.RE
|
|
.
|
|
.PP
|
|
Connect to a running
|
|
.B ampctld
|
|
with
|
|
.B ampctl
|
|
on the local host:
|
|
.
|
|
.sp
|
|
.RS 0.5i
|
|
.EX
|
|
$ ampctl -m2
|
|
.EE
|
|
.RE
|
|
.
|
|
.
|
|
.SH SECURITY
|
|
.
|
|
No authentication whatsoever; DO NOT leave this TCP port open wide to the
|
|
Internet. Please ask if stronger security is needed or consider using a
|
|
Secure Shell
|
|
.RB ( ssh (1))
|
|
tunnel.
|
|
.
|
|
.PP
|
|
As
|
|
.B ampctld
|
|
does not need any greater permissions than
|
|
.BR ampctl ,
|
|
it is advisable to not start
|
|
.B ampctld
|
|
as \(lqroot\(rq or another system user account in order to limit any
|
|
vulnerability.
|
|
.
|
|
.
|
|
.SH BUGS
|
|
.
|
|
The daemon is not detaching and backgrounding itself.
|
|
.PP
|
|
No method to exit the daemon so the
|
|
.BR kill (1)
|
|
command must be used to terminate it.
|
|
.
|
|
.PP
|
|
Multiple clients using the daemon may experience contention with the connected
|
|
amplifier.
|
|
.
|
|
.PP
|
|
Report bugs to:
|
|
.IP
|
|
.nf
|
|
.MT hamlib\-developer@lists.sourceforge.net
|
|
Hamlib Developer mailing list
|
|
.ME
|
|
.fi
|
|
.
|
|
.
|
|
.SH COPYING
|
|
.
|
|
This file is part of Hamlib, a project to develop a library that simplifies
|
|
radio, rotator, and amplifier control functions for developers of software
|
|
primarily of interest to radio amateurs and those interested in radio
|
|
communications.
|
|
.
|
|
.PP
|
|
Copyright \(co 2000-2010 Stephane Fillod
|
|
.br
|
|
Copyright \(co 2000-2018 the Hamlib Group (various contributors)
|
|
.br
|
|
Copyright \(co 2011-2019 Nate Bargmann
|
|
.
|
|
.PP
|
|
This is free software; see the file COPYING for copying conditions. There is
|
|
NO warranty; not even for MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
|
|
.
|
|
.
|
|
.SH SEE ALSO
|
|
.
|
|
.BR kill (1),
|
|
.BR ampctl (1),
|
|
.BR ssh (1),
|
|
.BR hamlib (7)
|
|
.
|
|
.
|
|
.SH COLOPHON
|
|
.
|
|
Links to the Hamlib Wiki, Git repository, release archives, and daily snapshot
|
|
archives:
|
|
.IP
|
|
.UR http://www.hamlib.org
|
|
hamlib.org
|
|
.UE .
|