Hamlib/tests/rotctld.1

463 wiersze
17 KiB
Groff

.\" Hey, EMACS: -*- nroff -*-
.\" First parameter, NAME, should be all caps
.\" Second parameter, SECTION, should be 1-8, maybe w/ subsection
.\" other parameters are allowed: see man(7), man(1)
.TH ROTCTLD "1" "January 12, 2016" "Hamlib" "Rotator Control Daemon"
.\" Please adjust this date whenever revising the manpage.
.\"
.\" Some roff macros, for reference:
.\" .nh disable hyphenation
.\" .hy enable hyphenation
.\" .ad l left justify
.\" .ad b justify to both left and right margins
.\" .nf disable filling
.\" .fi enable filling
.\" .br insert line break
.\" .sp <n> insert n+1 empty lines
.\" for manpage-specific macros, see man(7)
.SH NAME
rotctld \- Hamlib TCP rotator control daemon
.SH SYNOPSIS
.B rotctld
[\fIOPTION\fR]...
.SH DESCRIPTION
The \fBrotctld\fP program is an NEW \fBHamlib\fP rotator control daemon ready
for testing that handles client requests via TCP sockets. This allows multiple
user programs to share one rotator (this needs testing). Multiple rotators can
be controlled on different TCP ports by use of multiple \fBrotctld\fP processes.
The syntax of the commands are the same as \fBrotctl\fP. It is hoped that
\fBrotctld\fP will be especially useful for client authors using languages such
as Perl, Python, PHP, and others.
.PP
.\" TeX users may be more comfortable with the \fB<whatever>\fP and
.\" \fI<whatever>\fP escape sequences to invoke bold face and italics,
.\" respectively.
\fBrotctld\fP communicates to a client through a TCP socket using text
commands shared with \fBrotctl\fP. The protocol is simple, commands are sent
to \fBrotctld\fP on one line and \fBrotctld\fP responds to "get" commands with
the requested values, one per line, when successful, otherwise, it responds
with one line "RPRT x", where x is a negative number indicating the error code.
Commands that do not return values respond with the line "RPRT x", where x
is zero when successful, otherwise is a regative number indicating the error
code. Each line is terminated with a newline '\\n' character. This protocol
is primarily for use by the \fINET rotctl\fP (rot model 2) backend.
.PP
A separate \fBExtended Response\fP protocol extends the above
behavior by echoing the received command string as a header, any returned values
as a key: value pair, and the "RPRT x" string as the end of response marker
which includes the \fBHamlib\fP success or failure value. See the
\fIPROTOCOL\fP section for details. Consider using this protocol for clients
that will interact with \fBrotctld\fP directly through a TCP socket.
.PP
Keep in mind that \fBHamlib\fP is BETA level software.
While a lot of backend libraries lack complete rotator support, the basic
functions are usually well supported. The API may change without publicized
notice, while an advancement of the minor version (e.g. 1.1.x to 1.2.x)
indicates such a change.
.PP
Please report bugs and provide feedback at the e-mail address given in the
REPORTING BUGS section. Patches and code enhancements are also welcome.
.SH OPTIONS
This program follows the usual GNU command line syntax, with long
options starting with two dashes ('-').
.PP
Here is a summary of the supported options:
.TP
.B \-m, --model=id
Select rotator model number. See -l, "list" option below.
.TP
.B \-r, --rot-file=device
Use \fIdevice\fP as the file name of the port the rotator is connected.
Often a serial port, but could be a USB to serial adapter or USB port device.
Typically /dev/ttyS0, /dev/ttyS1, /dev/ttyUSB0, etc. on Linux or COM1, COM2,
etc. on Win32.
.TP
.B \-s, --serial-speed=baud
Set serial speed to \fIbaud\fP rate. Uses maximum serial speed from rotor
backend capabilities (set by -m above) as the default.
.TP
.B \-T, --listen-addr=IPADDR
Use \fIIPADDR\fP as the listening IP address. The default is ANY.
.TP
.B \-t, --port=number
Use \fInumber\fP as the TCP listening port. The default is 4533.
.sp
\fBN.B.\fP: As \fBrigctld\fP's default port is 4532, it is advisable to use odd
numbered ports for \fBrotctld\fP, e.g. 4533, 4535, 4537, etc.
.TP
.B \-L, --show-conf
List all config parameters for the rotator defined with -m above.
.TP
.B \-C, --set-conf=parm=val[,parm=val]*
Set config parameter. e.g. --set-conf=stop_bits=2
.sp
Use -L option for a list.
.TP
.B \-l, --list
List all model numbers defined in \fBHamlib\fP and exit. As of 1.2.15.1
the list is sorted by model number.
.sp
\fBN.B.\fP In Linux the list can be scrolled back using Shift-PageUp/
Shift-PageDown, or using the scrollbars of a virtual terminal in X or
the cmd window in Windows. The output can be piped to 'more' or 'less',
e.g. 'rotctld -l | more'.
.TP
.B \-u, --dump-caps
Dump capabilities for the rotator defined with -m above and exit.
.TP
.B \-v, --verbose
Set verbose mode, cumulative (see DIAGNOSTICS below).
.TP
.B \-h, --help
Show a summary of these options and exit.
.TP
.B \-V, --version
Show the version of \fBrotctld\fP and exit.
.PP
\fBN.B.\fP Some options may not be implemented by a given backend and will
return an error. This is most likely to occur with the \fI\-\-set-conf\fP
and \fI\-\-show-conf\fP options.
.PP
Please note that the backend for the rotator to be controlled,
or the rotator itself may not support some commands. In that case,
the operation will fail with a \fBHamlib\fP error code.
.SH COMMANDS
Commands can be sent over the TCP socket either as a single char, or as a
long command name plus the value(s) space separated on one '\\n' terminated
line. See \fIPROTOCOL\fP.
.PP
Since most of the \fBHamlib\fP operations have a \fIset\fP and a \fIget\fP
method, an upper case letter will be used for \fIset\fP methods whereas the
corresponding lower case letter refers to the \fIget\fP method. Each operation
also has a long name; prepend a backslash to send a long command name.
.PP
Example (Perl): `print $socket "\\\\dump_caps\\n";' to see what the rotor's
backend can do (NOTE: In Perl and many other languages a '\\' will need to be
escaped with a preceding '\\' so that even though two backslash characters
appear in the code, only one will be passed to \fBrotctld\fP. This is a
possible bug, beware!).
.PP
Please note that the backend for the rotator to be controlled, or the rotator
itself may not support some commands. In that case, the operation will fail
with a \fBHamlib\fP error message.
.PP
Here is a summary of the supported commands (In the case of "set" commands the
quoted string is replaced by the value in the description. In the case of "get"
commands the quoted string is the key name of the value returned.):
.TP
.B P, set_pos 'Azimuth' 'Elevation'
Set position: Azimuth and Elevation as double precision floating point values.
.TP
.B p, get_pos
Get position: 'Azimuth' and 'Elevation' as double precision floating point
values.
.TP
.B M, move 'Direction' 'Speed'
Move the rotator in a specific direction at the given rate.
.sp
Values are integers where Direction is defined as 2 = Up, 4 = Down, 8 = Left,
and 16 = Right. Speed is an integer between 1 and 100. Not all backends that
implement the move command use the Speed value. At this time only the gs232a
utilizes the Speed parameter.
.TP
.B S, stop
Stop the rotator.
.TP
.B K, park
Park the antenna.
.TP
.B C, set_conf 'Token' 'Value'
Set Token to Value.
.sp
Backend dependent. Needs testing.
.TP
.B R, reset 'Reset'
Reset the rotator.
.sp
Integer value of '1' for Reset All.
.TP
.B _, get_info
Get misc information about the rotator.
.sp
At the moment returns 'Model Name'.
.TP
.B w, send_cmd 'Cmd'
Send raw command string to rotator.
.sp
For binary protocols enter values as \\0xAA\\0xBB. Expect a 'Reply' from the
rotator which will likely be a binary block or an ASCII string.
.PP
\fBLocator Commands\fP
.PP
These commands offer conversions of Degrees Minutes Seconds to other formats,
Maidenhead square locator conversions and distance and azimuth conversions.
.TP
.B L, lonlat2loc 'Longitude' 'Latitude' 'Loc Len [2-12]'
Returns the Maidenhead locator for the given 'Longitude' and 'Latitude'.
.sp
Both are floating point values. The precision of the returned square is
controlled by 'Loc Len' which should be an even numbered integer value between
2 and 12.
.sp
For example, "+L -170.000000 -85.000000 12\\n" returns
"Locator: AA55AA00AA00\\n".
.TP
.B l, loc2lonlat 'Locator'
Returns 'Longitude' and 'Latitude' in decimal degrees at the approximate
center of the requested grid square (despite the use of double precision
variables internally, some rounding error occurs). West longitude is
expressed as a negative value. South latitude is expressed as a negative
value. Locator can be from 2 to 12 characters in length.
.sp
For example, "+l AA55AA00AA00\\n" returns "Longitude: -169.999983\\nLatitude:
-84.999991\\n".
.TP
.B D, dms2dec 'Degrees' 'Minutes' 'Seconds' 'S/W'
Returns 'Dec Degrees', a signed floating point value.
.sp
Degrees and Minutes are
integer values and Seconds is a floating point value. S/W is a flag with '1'
indicating South latitude or West longitude and '0' North or East (the flag is
needed as computers don't recognize a signed zero even though only the Degrees
value only is typically signed in DMS notation).
.TP
.B d, dec2dms 'Dec Degrees'
Returns 'Degrees' 'Minutes' 'Seconds' 'S/W'.
.sp
Values are as in dms2dec above.
.TP
.B E, dmmm2dec 'Degrees' 'Dec Minutes' 'S/W'
Returns 'Dec Degrees', a signed floating point value.
.sp
Degrees is an integer
value and Minutes is a floating point value. S/W is a flag with '1'
indicating South latitude or West longitude and '0' North or East (the flag is
needed as computers don't recognize a signed zero even though only the Degrees
value only is typically signed in DMS notation).
.TP
.B e, dec2dmmm 'Dec Deg'
Returns 'Degrees' 'Minutes' 'S/W'.
.sp
Values are as in dmmm2dec above.
.TP
.B B, qrb 'Lon 1' 'Lat 1' 'Lon 2' 'Lat 2'
Returns 'Distance' 'Azimuth' where Distance is in km and Azimuth is in degrees.
.sp
All Lon/Lat values are signed floating point numbers.
.TP
.B A, a_sp2a_lp 'Short Path Deg'
Returns 'Long Path Deg' or -RIG_EINVAL upon input error..
.sp
Both are floating point values within the range 0.00 to 360.00.
.TP
.B a, d_sp2d_lp 'Short Path km'
Returns 'Long Path km'.
.sp
Both are floating point values.
.SH PROTOCOL
\fBDefault Protocol\fP
.PP
The \fBrotctld\fP protocol is intentionally simple. Commands are entered on
a single line with any needed values. In Perl, reliable results are obtained
by terminating each command string with a newline character, '\\n'.
.sp
Example \fIset\fP (Perl code):
.sp
print $socket "P 135 10\\n";
.sp
print $socket "\\\\set_pos 135 10\\n"; # escape leading '\\'
.PP
A one line response will be sent as a reply to \fIset\fP commands,
"RPRT \fIx\fP\\n" where \fIx\fP is the Hamlib error code with '0'
indicating success of the command.
.PP
Responses from \fBrotctld\fP \fIget\fP commands are text values and match the
same tokens used in the \fIset\fP commands. Each value is returned on its own
line. On error the string "RPRT \fIx\fP\\n" is returned where \fIx\fP is the
Hamlib error code.
.sp
Example \fIget\fP (Perl code):
.sp
print $socket "p\\n";
.br
"135"
.br
"10"
.PP
Most \fIget\fP functions return one to three values. A notable exception is
the \fI\\dump_caps\fP function which returns many lines of key:value pairs.
.PP
This protocol is primarily used by the \fINET rotctl\fP (rotctl model 2) backend
which allows applications already written for Hamlib's C API to take advantage
of \fBrotctld\fP without the need of rewriting application code. An
application's user can select rotor model 2 ("NET rotctl") and then set
rot_pathname to "localhost:4533" or other network host:port (set by the \fI-t\fP
option above).
.PP
\fBExtended Response Protocol\fP
.PP
An \fIEXPERIMENTAL\fP Extended Response protocol has been introduced into
\fBrotctld\fP as of February 10, 2010. This protocol adds several rules to the
strings returned by \fBrotctld\fP and adds a rule for the command syntax.
.PP
1. The command received by \fBrotctld\fP is echoed with its long command name
followed by the value(s) (if any) received from the client terminated by the
specified response separator as the first record of the response.
.PP
2. The last record of each block is the string "RPRT \fIx\fP\\n" where \fIx\fP
is the numeric return value of the Hamlib backend function that was called by
the command.
.PP
3. Any records consisting of data values returned by the rotor backend are
prepended by a string immediately followed by a colon then a space and then the
value terminated by the response separator. e.g. "Azimuth: 90.000000\\n" when
the command was prepended by '+'.
.PP
4. All commands received will be acknowledged by \fBrotctld\fP with records from
rules 1 and 2. Records from rule 3 are only returned when data values must be
returned to the client.
.PP
An example response to a \fI+P\fP command command sent from the shell prompt
(note the prepended '+'):
.sp
$ echo "+P 90 45" | nc -w 1 localhost 4533
.br
set_pos: 90 45
.br
RPRT 0
.PP
In this case the long command name and values are returned on the first line and
the second line contains the end of block marker and the numeric rotor backend
return value indicating success.
.PP
An example response to a \fI+\\get_pos\fP query:
.sp
$ echo "+\\get_pos" | nc -w 1 localhost 4533
.br
get_pos:
.br
Azimuth: 90.000000
.br
Elevation: 45.000000
.br
RPRT 0
.PP
In this case, as no value is passed to \fBrotctld\fP, the first line consists
only of the long command name. The final line shows that the command was
processed successfully by the rotor backend.
.PP
Invoking the Extended Response protocol requires prepending a command with a
punctuation character. As shown in the examples above, prepending a '+'
character to the command results in the responses being separated by a newline
character ('\\n'). Any other punctuation character recognized by the C
\fIispunct()\fP function except '\\', '?', or '_' will cause that character to
become the response separator and the entire response will be on one line.
.PP
Separator character summary:
.TP
.B '+'
.br
Each record of the response is appended with a newline ('\\n').
.TP
.B ';', '|', or ','
.br
Each record of the response is appended by the given character resulting in
entire response on one line.
.sp
Common record separators for text representations of spreadsheet data, etc.
.TP
.B '?'
.br
Reserved for 'help' in rotctl short command
.TP
.B '_'
.br
Reserved for \\get_info short command
.TP
.B '#'
.br
Reserved for comments when reading a command file script
.sp
Other punctuation characters have not been tested! Use at your own risk.
.PP
For example, invoking a \fI;\\get_pos\fP query with a leading ';' returns:
.sp
get_pos:;Azimuth: 90.000000;Elevation: 45.000000;RPRT 0
.sp
Or, using the pipe character '|' returns:
.sp
get_pos:|Azimuth: 90.000000|Elevation: 45.000000|RPRT 0
.sp
And a \\set_pos command prepended with a '|' returns:
.sp
set_pos: 135 22.5|RPRT 0
.PP
Such a format will allow reading a response as a single event using a preferred
response separator. Other punctuation characters have not been tested!
.PP
All commands with the exception of \fI\\set_conf\fP have been tested with the
Extended Response protocol and the included \fBtestrotctld.pl\fP script.
.PP
.SH EXAMPLES
Start \fBrotctld\fP for a Ham IV rotor with the RotorEZ installed using a
USB-to-serial adapter and backgrounding:
.sp
$ rotctld -m 401 -r /dev/ttyUSB1 &
.sp
Start \fBrotctld\fP for RotorEZ using COM2 on Win32:
.sp
$ rotctl -m 401 -r COM2
.sp
Connect to the already running \fBrotctld\fP, and set position to
135.0 degrees azimuth and 30.0 degrees elevation with a 1 second read timeout
from the shell prompt:
.sp
$ echo "\\set_pos 135.0 30.0" | nc -w 1 localhost 4533
.sp
Connect to a running \fBrotctld\fP with \fBrotctl\fP on the local host:
.sp
$ rotctl -m2
.SH DIAGNOSTICS
The \fB-v\fP, \fB--version\fP option allows different levels of diagnostics
to be output to \fBstderr\fP and correspond to -v for BUG, -vv for ERR,
-vvv for WARN, -vvvv for VERBOSE, or -vvvvv for TRACE.
.PP
A given verbose level is useful for providing needed debugging information to
the email address below. For example, TRACE output shows all of the values
sent to and received from the rotator which is very useful for rotator backend
library development and may be requested by the developers. See the
\fBREADME.betatester\fP and \fBREADME.developer\fP files for more information.
.SH SECURITY
No authentication whatsoever; DO NOT leave this TCP port open wide to the
Internet. Please ask if stronger security is needed or consider using an
SSH tunnel.
.PP
As \fBrotctld\fP does not need any greater permissions than \fBrotctl\fP, it
is advisable to not start \fBrotctld\fP as \fIroot\fP or another system user
account in order to limit any vulnerability.
.SH BUGS
The daemon is not detaching and backgrounding itself.
.PP
Much testing needs to be done.
.SH REPORTING BUGS
Report bugs to <hamlib-developer@lists.sourceforge.net>.
.PP
We are already aware of the bugs in the previous section :-)
.SH AUTHORS
Written by Stephane Fillod, Nate Bargmann, and the Hamlib Group
.PP
<http://www.hamlib.org>.
.SH COPYRIGHT
Copyright \(co 2000-2009 Stephane Fillod
.br
Copyright \(co 2011-2013 Nate Bargmann
.br
Copyright \(co 2000-2009 the Hamlib Group.
.PP
This is free software; see the source for copying conditions.
There is NO warranty; not even for MERCHANTABILITY
or FITNESS FOR A PARTICULAR PURPOSE.
.SH SEE ALSO
.BR rotctl (1),
.BR hamlib (3)