There was an inconsistency in whether the CAT terminator character is
included in returned messages. It now follows the comment in
kenwood_transaction() i.e. strips of the terminator and returns a
message length that reflects that.
Bill reports his TS-440 returns 38 chars instead of the default 29.
This patch defines iflen of 38 for the ts440 backend and implements
necssary support in the ic10 backend.
git-svn-id: https://hamlib.svn.sourceforge.net/svnroot/hamlib/trunk@3067 7ae35d74-ebe9-4afe-98af-79ac388436b8
Among the changes:
I finally had the time to build the CAT interface for my TS450 and
discovered a couple of new commands.
MX; MX0; MX1; is used to activate the AIP function
FL; FLXXXYYY; is used to set the filters.
I made a perl script to try every possible two-letters command. If
amyone is interested, at their own risk, just ask.
I've then modified and optimized the kenwood driver:
- moved MD_ defined to .h
- added init/cleanup
- ts450_get_mode -> kenwood_get_mode_if
- support reading memory channel freq within kenwood_get_freq
- added kenwood_safe_transaction as an helper with result len check
- added kenwood_get_if
- added get_level for RIG_LEVEL_CWPITCH
- set/get for RIG_FUNC_AIP
- replaced ts140/680 get_mode and get_freq
- removed the delay on the ts450. it works just fine without it.
=============================
the attached patch requires the first one I sent and
addresses a few remaining issues
- converted 8 spaces to tabs
- added kenwood_mode_table
- added kenwood_simple_transaction helper func
- use kenwood2rmode and rmode2kenwood where possible
- some code cleanup
- use kenwood_safe/simple_transaction where possible
- added kenwood_get_mem_if (ts140,ts450,ts680,ts690,ts850)
- added kenwood_get_channel (ts450,ts850)
- added FUNC_FINE_STEP (commented out, we have no more func slots)
- added LEVEL_CWPITCH (set)
- no reason to have ts850_set_func, ts850_set_level
- ... ts480_get/set_ant, ts480_set_func
- ... ts570_set/get_ant, ts570_get_channel, ts570_get_rit
- ... ts680_set_func
- ... ts790_get_mode, ts790_get_vfo
this patch is a bit more extensive and tested only on the TS450.
feedback will be appreciated.
where I removed code I took care to verify that the generic
code in kenwood.c worked in the same way.
git-svn-id: https://hamlib.svn.sourceforge.net/svnroot/hamlib/trunk@2591 7ae35d74-ebe9-4afe-98af-79ac388436b8