ICOM test via rigctl
Rig command: w \0xfe\0xfe\0x58\0xe0\0x03\0xfd
Reply:\0xFE\0xFE\0x58\0xE0\0x03\0xFD\0xFE\0xFE\0xE0\0x58\0x03\0x00\0x50\0x09\0x14\0x00\0xFD 17
Rig command: W \0xfe\0xfe\0x58\0xe0\0x03\0xfd 17
Reply:\0xFE\0xFE\0x58\0xE0\0x03\0xFD\0xFE\0xFE\0xE0\0x58\0x03\0x00\0x50\0x09\0x14\0x00\0xFD 17
Rig command: w FA;
send_cmd: error = Invalid parameter
Rig command: W FA; 14
send_cmd_rx: error = Invalid parameter
ICOM test via rigctld
Rig command: w \0xfe\0xfe\0x58\0xe0\0x03\0xfd
Reply:\0xFE\0xFE\0x58\0xE0\0x03\0xFD\0xFE\0xFE\0xE0\0x58\0x03\0x00\0x50\0x09\0x14\0x00\0xFD 17
Rig command: W \0xfe\0xfe\0x58\0xe0\0x03\0xfd 17
Reply:\0xFE\0xFE\0x58\0xE0\0x03\0xFD\0xFE\0xFE\0xE0\0x58\0x03\0x00\0x50\0x09\0x14\0x00\0xFD 17
Rig command: w FA;
Reply:RPRT -1
Rig command: W FA; 14
Reply:RPRT -1
Kenwood test via rigctl
Rig command: w FA;
Reply:FA00014074000;
Rig command: W FA; 14
Reply:FA00014074000;
Rig command: w \0x46\0x41\0x3b
Reply:FA00014074000;
Rig command: W \0x46\0x41\0x3b 14
Reply:FA00014074000;
Kenwood test via rigctld
Rig command: w FA;
Reply:FA00014074000;
Rig command: W FA; 14
Reply:FA00014074000;
Rig command: w \0x46\0x41\0x3b
Reply:FA00014074000;
Rig command: W \0x46\0x41\0x3b 14
Reply:FA00014074000;
So we can now do this...write once to see how many bytes you get back
Rig command: w \0xfe\0xfe\0x58\0xe0\0x03\0xfd
Cmd:\0xFE\0xFE\0x58\0xE0\0x03\0xFD\0xFE\0xFE\0xE0\0x58\0x03\0x00\0x00\0x09\0x14\0x00\0xFD 17
Then use 'W' to write the command with the # of bytes to expect -- no timeout this way
Rig command: W \0xfe\0xfe\0x58\0xe0\0x03\0xfd 17
Cmd:\0xFE\0xFE\0x58\0xE0\0x03\0xFD\0xFE\0xFE\0xE0\0x58\0x03\0x00\0x00\0x09\0x14\0x00\0xFD 17
Fix declarations after statements
Remove some !rig checks...we either don't need them or need them everywhere with a new error code
If you pass a NULL rig you get what you deserve :-)
Now responds with hex string just like the input and the # of bytes
Will get hex string response for any binary data from rig from any command
Next step is to implement W command for known # of bytes in response to avoid the timeout
This found tons of errors in rig_debug statements
So this patch cleans up all the files that were producing warnings or errors
This should fix a few segfaults when running with debug turned on
Because some rigs lock their front panel when opened for CAT it is
helpful to call rig_close() in rigctld when no clients are
connected. This change does that.
A CTRL+C handler is also added to allow rig_close() to be called
during exit.
on the real rig. In rigctl_parse.c, we make sure that invalid attempts to
so so are mapped on a safe variant.
Second change to netrigctl: drain the input line before sending a new
command, to reach sync again after a timeout.
Separate FT-891 features
Fix rigctl and rigctld to not abort on function not available
Change Yaesu detection of FA length to automatic method instead of rig specific