16 data points for S Meter Calibration

git-svn-id: https://hamlib.svn.sourceforge.net/svnroot/hamlib/trunk@2479 7ae35d74-ebe9-4afe-98af-79ac388436b8
Hamlib-1.2.9
Terry Embry, KJ4EED 2008-11-26 22:16:00 +00:00
rodzic 8f350baa93
commit f38ec23e60
1 zmienionych plików z 18 dodań i 5 usunięć

Wyświetl plik

@ -8,7 +8,7 @@
* via serial interface to an FT-950 using the "CAT" interface
*
*
* $Id: ft950.h,v 1.2 2008-11-01 22:39:07 fillods Exp $
* $Id: ft950.h,v 1.3 2008-11-26 22:16:00 mrtembry Exp $
*
*
* This library is free software; you can redistribute it and/or
@ -68,11 +68,24 @@
RIG_OP_TO_VFO|RIG_OP_FROM_VFO)
/* TBC */
#define FT950_STR_CAL { 3, \
#define FT950_STR_CAL { 16, \
{ \
{ 10, -60 }, /* S0 */ \
{ 125, 0 }, /* S9 */ \
{ 240, 60 } /* +60 */ \
{ 0, -54 }, /* S0 */ \
{ 12, -48 }, /* S1 */ \
{ 27, -42 }, /* S2 */ \
{ 40, -36 }, /* S3 */ \
{ 55, -30 }, /* S4 */ \
{ 65, -24 }, /* S5 */ \
{ 80, -18 }, /* S6 */ \
{ 95, -12 }, /* S7 */ \
{ 112, -6 }, /* S8 */ \
{ 130, 0 }, /* S9 */ \
{ 150, 10 }, /* +10 */ \
{ 172, 20 }, /* +20 */ \
{ 190, 30 }, /* +30 */ \
{ 220, 40 }, /* +40 */ \
{ 240, 50 }, /* +50 */ \
{ 255, 60 }, /* +60 */ \
} }