kopia lustrzana https://github.com/Hamlib/Hamlib
For all kenwoods remove the ID; check of the RX; command
TS-480 is not returning RX0; as the manual says May want to consider validating PTT instead https://github.com/Hamlib/Hamlib/issues/338pull/345/head
rodzic
a19169a6b0
commit
4177dde4e0
|
@ -323,6 +323,12 @@ transaction_write:
|
|||
}
|
||||
}
|
||||
|
||||
// we're not going to do the verify on RX cmd
|
||||
// Seems some rigs (like TS-480) return "?" when RX is done while PTT=OFF
|
||||
// So we'll skip the checks just on this one command for now
|
||||
// The TS-480 PC Control says RX; should return RX0; but it doesn't
|
||||
if (retval == RIG_OK && strncmp(cmdstr, "RX", 2) == 0) goto transaction_quit;
|
||||
|
||||
if (!datasize)
|
||||
{
|
||||
rig->state.hold_decode = 0;
|
||||
|
|