@ -1100,15 +1100,6 @@ int kenwood_open(RIG *rig)
|
|||
// mismatched IDs can still be tested
|
||||
rig->state.rigport.retry = retry_save;
|
||||
|
||||
|
||||
// TS-990S needs to ensure all RM meters are turned off as first one with read on gets read
|
||||
// Any RM commands need to be ON/READ/OFF to allow other apps or threads to read meters
|
||||
|
||||
if (RIG_IS_TS990S)
|
||||
{
|
||||
kenwood_transaction(rig, "RM10;RM20;RM30;RM40;RM50;RM60;", NULL, 0);
|
||||
}
|
||||
|
||||
RETURNFUNC(RIG_OK);
|
||||
}
|
||||
|
||||
|
@ -3471,6 +3462,54 @@ int get_kenwood_level(RIG *rig, const char *cmd, float *fval, int *ival)
|
|||
RETURNFUNC(RIG_OK);
|
||||
}
|
||||
|
||||
/* Helper to get and parse meter values using RM
|
||||
* Note that we turn readings on, but nothing off.
|
||||
* 'pips' is the number of LED bars lit in the digital meter, max=70
|
||||
*/
|
||||
int get_kenwood_meter_reading(RIG *rig, char meter, int *pips)
|
||||
{
|
||||
char reading[9]; /* 8 char + '\0' */
|
||||
int retval;
|
||||
char target[] = "RMx1"; /* Turn on reading this meter */
|
||||
|
||||
target[2] = meter;
|
||||
retval = kenwood_transaction(rig, target, NULL, 0);
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
return retval;
|
||||
}
|
||||
|
||||
/* Read the first value */
|
||||
retval = kenwood_transaction(rig, "RM", reading, sizeof(reading));
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
return retval;
|
||||
}
|
||||
|
||||
/* Find the one we want */
|
||||
while (strncmp(reading, target, 3) != 0)
|
||||
{
|
||||
/* That wasn't it, get the next one */
|
||||
retval = kenwood_transaction(rig, NULL, reading, sizeof(reading));
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
return retval;
|
||||
}
|
||||
|
||||
if (reading[0] != target[0] || reading[1] != target[1])
|
||||
{
|
||||
/* Somebody else's data, bail */
|
||||
return -RIG_EPROTO;
|
||||
}
|
||||
}
|
||||
|
||||
sscanf(reading + 3, "%4d", pips);
|
||||
return RIG_OK;
|
||||
|
||||
}
|
||||
|
||||
/*
|
||||
* kenwood_get_level
|
||||
|
|
|
@ -264,6 +264,7 @@ int kenwood_get_trn(RIG *rig, int *trn);
|
|||
/* only use if returned string has length 6, e.g. 'SQ011;' */
|
||||
int get_kenwood_level(RIG *rig, const char *cmd, float *fval, int *ival);
|
||||
int get_kenwood_func(RIG *rig, const char *cmd, int *status);
|
||||
int get_kenwood_meter_reading(RIG *rig, char meter, int *pips);
|
||||
|
||||
extern const struct rig_caps ts950s_caps;
|
||||
extern const struct rig_caps ts950sdx_caps;
|
||||
|
|
|
@ -106,56 +106,6 @@ int kenwood_ts890_set_level(RIG *rig, vfo_t vfo, setting_t level, value_t val)
|
|||
return kenwood_transaction(rig, levelbuf, NULL, 0);
|
||||
}
|
||||
|
||||
/* Helper to get and parse meter values using RM
|
||||
* Note that we turn readings on, but nothing off.
|
||||
* 'pips' is the number of LED bars lit in the digital meter, max=70
|
||||
*/
|
||||
static
|
||||
int ts890_get_meter_reading(RIG *rig, char meter, int *pips)
|
||||
{
|
||||
char reading[9]; /* 8 char + '\0' */
|
||||
int retval;
|
||||
char target[] = "RMx1"; /* Turn on reading this meter */
|
||||
|
||||
target[2] = meter;
|
||||
retval = kenwood_transaction(rig, target, NULL, 0);
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
return retval;
|
||||
}
|
||||
|
||||
/* Read the first value */
|
||||
retval = kenwood_transaction(rig, "RM", reading, sizeof(reading));
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
return retval;
|
||||
}
|
||||
|
||||
/* Find the one we want */
|
||||
while (strncmp(reading, target, 3) != 0)
|
||||
{
|
||||
/* That wasn't it, get the next one */
|
||||
retval = kenwood_transaction(rig, NULL, reading, sizeof(reading));
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
return retval;
|
||||
}
|
||||
|
||||
if (reading[0] != target[0] || reading[1] != target[1])
|
||||
{
|
||||
/* Somebody else's data, bail */
|
||||
return -RIG_EPROTO;
|
||||
}
|
||||
}
|
||||
|
||||
sscanf(reading + 3, "%4d", pips);
|
||||
return RIG_OK;
|
||||
|
||||
}
|
||||
|
||||
int kenwood_ts890_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
||||
{
|
||||
char ackbuf[50];
|
||||
|
@ -253,7 +203,7 @@ int kenwood_ts890_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
|||
return RIG_OK;
|
||||
|
||||
case RIG_LEVEL_ALC:
|
||||
retval = ts890_get_meter_reading(rig, '1', &levelint);
|
||||
retval = get_kenwood_meter_reading(rig, '1', &levelint);
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
|
@ -264,7 +214,7 @@ int kenwood_ts890_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
|||
return RIG_OK;
|
||||
|
||||
case RIG_LEVEL_SWR:
|
||||
retval = ts890_get_meter_reading(rig, '2', &levelint);
|
||||
retval = get_kenwood_meter_reading(rig, '2', &levelint);
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
|
@ -287,7 +237,7 @@ int kenwood_ts890_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
|||
return RIG_OK;
|
||||
|
||||
case RIG_LEVEL_COMP_METER:
|
||||
retval = ts890_get_meter_reading(rig, '3', &levelint);
|
||||
retval = get_kenwood_meter_reading(rig, '3', &levelint);
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
|
@ -301,7 +251,7 @@ int kenwood_ts890_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
|||
return RIG_OK;
|
||||
|
||||
case RIG_LEVEL_ID_METER:
|
||||
retval = ts890_get_meter_reading(rig, '4', &levelint);
|
||||
retval = get_kenwood_meter_reading(rig, '4', &levelint);
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
|
@ -312,7 +262,7 @@ int kenwood_ts890_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
|||
return RIG_OK;
|
||||
|
||||
case RIG_LEVEL_VD_METER:
|
||||
retval = ts890_get_meter_reading(rig, '5', &levelint);
|
||||
retval = get_kenwood_meter_reading(rig, '5', &levelint);
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
|
@ -324,7 +274,7 @@ int kenwood_ts890_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
|||
|
||||
case RIG_LEVEL_TEMP_METER:
|
||||
#if 0
|
||||
retval = ts890_get_meter_reading(rig, '6', &levelint);
|
||||
retval = get_kenwood_meter_reading(rig, '6', &levelint);
|
||||
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
|
|
|
@ -647,16 +647,12 @@ int ts990s_get_level(RIG *rig, vfo_t vfo, setting_t level, value_t *val)
|
|||
break;
|
||||
|
||||
case RIG_LEVEL_SWR:
|
||||
// we need to turn on read, read it, and turn it off again
|
||||
// first RM meter with read on is the that gets read with RM;
|
||||
retval = kenwood_safe_transaction(rig, "RM21;RM;RM20", lvlbuf, sizeof(lvlbuf), 8);
|
||||
|
||||
retval = get_kenwood_meter_reading(rig, '2', &lvl);
|
||||
if (retval != RIG_OK)
|
||||
{
|
||||
return retval;
|
||||
}
|
||||
|
||||
sscanf(lvlbuf, "RM2%d", &lvl);
|
||||
val->f = rig_raw2val_float(lvl, &rig->caps->swr_cal);
|
||||
val->f = round(val->f*10)/10.0; // 1 decimal place precision
|
||||
break;
|
||||
|
|