Update README.md
rodzic
3c4e5d648e
commit
1cf78a2c54
26
README.md
26
README.md
|
@ -3,8 +3,30 @@
|
|||
### Official conversation group - https://groups.io/g/ATU100
|
||||
### Schematic and assembly instruction by VK3PE - http://carnut.info/ATU_N7DDC/ATU-10/ATU-10_by-vk3pe_build_info/ATU-10_vk3pe_V1.2_ALL_INFO_290921.pdf
|
||||
|
||||
###### AON FW is always on
|
||||
no automatic power off. Use button to power off after using to avoid discharging the battery.
|
||||
###### New in FW version 1.6
|
||||
1 - New better meassurement formula for Power and SWR calculation, compensation and calibration.
|
||||
2 - Setting by Cells control implementation. There are 10 cells you can find opening a FW .hex file in Notepad++ program as Intel HEX file.
|
||||
At the end by address EEE0 and EEF0 you can see them and change values. After changing any value you must to correct a checksumm for each
|
||||
changed string. Copy the needed string into Checsumm.htm and get correct checksumm. It should be green coolor before you can save changed .hex FW file.
|
||||
|
||||
[![](https://github.com/Dfinitski/ATU-10-10W-QRP-antenna-tuner/blob/main/Photos/tuner_2.jpg)](https://github.com/Dfinitski/ATU-10-10W-QRP-antenna-tuner/blob/main/Photos/tuner_2.jpg)
|
||||
|
||||
Cells description:
|
||||
1) Time to display off in minutes, 5 mins by default, 0 to always on display
|
||||
2) time to power off in minutes, 30 mins by default, 0 to always power on
|
||||
3) relay's delay time, voltage applied to coiles in ms, 7 ms by default
|
||||
4) min power to start tuning in ten's parts of Watt, 10 by default (1.0 W). This value can not be 0
|
||||
5) max power to start tuning in watts, 15 by default
|
||||
6) Delta SWR to auto start tuning in ten's parts SWR, 13 by default (SWR = 1.3)
|
||||
7) Auto mode 1 for activate or 0 to off. 1 by default
|
||||
8) Calibration coefficient for 1W power, 4 by default for BAT41 diodes
|
||||
9) calibration coefficient for 10W power, 14 by default for BAT41 diodes
|
||||
10) Peak detector time for Power meassurement in tens ms, 60 (600ms)
|
||||
|
||||
If you are using 1N5711 diodes in the RF detector, you can calibrate the power meassurement.
|
||||
Apply known 1W of power on 7MHz and change cell 8 for correct value.
|
||||
Apply known 10W of power on 7MHw and change cell 9 for correct value.
|
||||
Repeat it couple times to reach a good result.
|
||||
|
||||
###### New in FW version 1.5
|
||||
1 - Tuning algorithm improvement
|
||||
|
|